With underfloor heating, all pipe loops come together in one place: the heating manifold. It distributes the hot heating water to the individual rooms, collects the return and ensures that each room receives the right amount of water. When choosing a manifold for underfloor heating, you should therefore look at more than just the number of connections.
In this guide we explain how a manifold is built, how to work out the number of heating circuits you need, what role flow meters play in hydraulic balancing and what to look out for during installation.
How a heating manifold is built
A heating manifold consists of two parallel bars. The flow bar distributes the heating water to the circuits, and the return bar collects the cooled water again. The return usually has valves that accept actuators, through which the room thermostats open and close the individual circuits. On many models the flow bar has flow meters that allow the water quantity per circuit to be read and adjusted.
There are also air vents, fill and drain cocks and brackets for mounting in the manifold cabinet. The underfloor heating pipes are usually connected via compression fittings with Eurocone. Manifolds are available in stainless steel, brass or plastic; stainless steel is robust and widely used.
How many heating circuits you need
As a rule, each room gets at least one heating circuit of its own so that it can be controlled separately. Larger rooms are split into several circuits because a single circuit cannot be any length. Manufacturers and technical literature often quote a maximum pipe length of around 80 to 100 metres per circuit, depending on pipe diameter and laying spacing. It is also important that the circuits on one manifold are of similar length so that they can be balanced well.
An example: a flat with living room, kitchen, two bedrooms, bathroom and hallway can manage with six to eight circuits if the living room is split into two. When choosing, consider planning one spare outlet in case a room is later split or added. The exact circuit layout follows from the heat load calculation and the laying plan.
Flow meters and hydraulic balancing
Short heating circuits have less resistance than long ones. Without balancing, too much water therefore flows through the short circuits, while the rooms with long circuits do not warm up properly. During hydraulic balancing each circuit is set to the calculated water quantity. The longest circuits usually remain fully open, while the shorter ones are throttled.
Flow meters on the flow bar make this much easier, as you read the set quantity directly in litres per minute. Without flow meters, setting is done via presetting values on the valves, which also works but is less intuitive. Why balancing is mandatory for many systems is explained in our guide Hydraulic balancing.
| Equipment | Advantage | Note |
|---|---|---|
| With flow meters | Water quantity can be read and set directly | Somewhat higher price |
| Without flow meters | Cheaper, more compact | Setting via presetting values from a table |
Connection to the heating system: mixer or direct
Underfloor heating works with low flow temperatures. If it is supplied together with radiators by a boiler that delivers higher temperatures, it needs a control unit that lowers the temperature. For this there are constant temperature control sets with pump and thermostatic valve that are fitted directly in front of the manifold, or a mixed heating circuit in the boiler room. With a heat pump, which delivers low temperatures anyway, the manifold can often be connected directly.
The lower the flow temperature, the more efficiently heat pumps and condensing boilers work. More on this in our guide Lowering the flow temperature. Manifolds, control sets and accessories are available in our underfloor heating category.
Installation and manifold cabinet
Ideally the manifold sits centrally in the flat so that the supply pipes to the rooms are as short as possible. A manifold cabinet is common, either recessed into the wall or surface mounted. The cabinet size depends on the overall width of the manifold including isolating valves and, if applicable, the control set. Make sure that actuators, flow meters and air vents remain easily accessible later.
After connection, the system is flushed, filled, vented and pressure tested before the screed is laid. These tasks and hydraulic balancing should be carried out by a contractor. Tips on venting can be found in our guide Bleeding the heating.
Material and quality compared
Stainless steel manifolds are corrosion resistant, comparatively light and available in many versions. Brass manifolds are also widespread and robust, often somewhat heavier and more compact. Plastic manifolds are mainly found in system solutions from individual manufacturers. More important in everyday use than the base material are easy to read flow meters, valves with the right thread for the actuators of your control system and sufficient spacing between outlets so that the pipes can be connected neatly.
Also check the accessories: end pieces with air vent and drain, ball valves for flow and return and sound insulated brackets are included with many manifolds, while others require them to be ordered separately. Before buying, check whether the connections match your heating pipe, usually 1 inch female or male thread. Suitable actuators depend on the valve connection, frequently M30 by 1.5.
Frequently asked questions
Can I extend a manifold later?
Many systems can be extended modularly, but this depends on the manufacturer. It is easier to plan one spare outlet from the start.
Do I really need flow meters?
No, balancing is also possible using presetting values. Flow meters, however, make setting and later checks much easier.
Which connection suits my pipes?
Outlets with Eurocone are common. The right compression fitting depends on the diameter and wall thickness of the pipe, for example 16 by 2 millimetres.
Where should the manifold be located?
As centrally as possible in the flat or on the floor, so that the supply pipes to the rooms stay short and the heating circuits are of similar length. A place in the hallway or a storage room is common, as the cabinet remains easily accessible there and does not get in the way.
Conclusion
The heating manifold is the control centre of underfloor heating. Plan at least one circuit per room, split large rooms and keep circuit lengths similar. Flow meters make hydraulic balancing noticeably easier, and a constant temperature control set is needed if the heat generator supplies higher temperatures. Installation and balancing are carried out by a contractor. Manifolds, control sets and fittings are available in our zencQ category.