In summer, the old oil or gas boiler often only runs for hot water, and at a low utilisation rate. If you heat water electrically with a water heater or an instantaneous water heater, on the other hand, you will see the costs on every electricity bill. A domestic hot water heat pump addresses exactly this: it extracts heat from the room air and uses it to heat the water in the integrated cylinder. Depending on the conditions, one kilowatt hour of electricity becomes several kilowatt hours of heat.
In this guide, we explain how a domestic hot water heat pump works, which operating modes are available and what requirements the installation room must meet. We also show how well the unit can be combined with photovoltaics, what to bear in mind regarding hygiene and what applies to funding in 2026.
How a domestic hot water heat pump works
A domestic hot water heat pump works on the same principle as a refrigerator, only in reverse. A fan draws in air and passes it over an evaporator. There, a refrigerant absorbs the heat from the air and evaporates. An electrically driven compressor increases the pressure and temperature of the refrigerant. In the condenser, it then transfers the heat to the drinking water in the cylinder. The cooled, slightly dehumidified air flows out again.
Heat pump and cylinder usually form a compact unit, as with this hot water heat pump. Common cylinder sizes are 200 to 300 litres. A built-in electric immersion heater serves as a backup, for example when demand is very high or for heating to higher temperatures. Many units also have a smooth-tube heat exchanger that allows a boiler or solar thermal system to be integrated.
COP and electricity consumption of a hot water heat pump

How much heat a unit produces from one kilowatt hour of electricity is described by the coefficient of performance, the COP. For hot water heat pumps, it is determined according to DIN EN 16147, which also takes a draw-off profile into account. The warmer the intake air and the lower the target temperature, the better the value. Data sheet values can therefore only be compared if the test conditions are the same, such as the air temperature and the draw-off profile. According to manufacturers, good units achieve values of around 3 to 4.
A simplified calculation shows the order of magnitude: if a household needs 3,000 kilowatt hours of heat for hot water per year, an electric immersion heater needs around 3,000 kilowatt hours of electricity for this. A domestic hot water heat pump with an average coefficient of performance of 3 mathematically needs about 1,000 kilowatt hours. In everyday use, the result depends on the air temperature, draw-off behaviour, cylinder losses and how often the immersion heater is used.
| Operating mode | Air source | Typical use |
|---|---|---|
| Recirculated air | Air from the installation room | Basement, utility or boiler room |
| Extract air | Extract air from bathroom, kitchen or WC via ducts | Combination with residential ventilation |
| Outdoor air | Outdoor air via ducts | Small or heated installation rooms |
Installation location and requirements
In recirculated air mode, the installation room is the heat source for a domestic hot water heat pump. It therefore has to be large enough to prevent the air from cooling down too much. Many manufacturers require a room volume of at least 20 cubic metres for units with 250 to 300 litres. If the room is smaller, the unit can often be connected via air ducts to a neighbouring room or to the outdoor air. Minimum and maximum temperatures for the intake air also apply and are stated in the data sheet.
Unheated basement rooms where waste heat is produced anyway, for example by a boiler, freezer or washing machine, are ideal. Because the heat pump cools and dehumidifies the air, it can even be useful there, for example in a storage cellar. You can read how to ventilate basements correctly in the guide Ventilating the Basement in Summer. In heated rooms, however, recirculated air mode is unfavourable, because the unit then indirectly takes heat from the heating system.
Also plan for a condensate drain, a secure floor for the weight of the filled cylinder and sufficient clearance for maintenance work. Newer units often use the refrigerant R290, i.e. propane. Because it is flammable, special installation conditions set by the manufacturer apply, and you should observe them without fail.
Combining with photovoltaics and an existing heating system

A domestic hot water heat pump goes well with a photovoltaic system. The cylinder acts like a battery for heat: the unit preferably heats the water when solar power is available during the day. Many models have an input for a signal from the inverter or energy manager for this purpose, often referred to as an SG Ready contact. When there is surplus solar power, the target temperature can then be set higher so that more heat is stored for the evening. Because the water is then hotter than usual, a thermostatic mixing valve at the hot water outlet prevents the risk of scalding at the taps.
The unit can also be combined with an existing heating system. In summer, the heat pump takes care of the hot water on its own and the boiler can remain switched off. In winter, the boiler can provide support via the built-in heat exchanger. Pay attention to drinking water hygiene: to prevent legionella, the cylinder should regularly be heated to a sufficiently high temperature, using the immersion heater if necessary. The guide Legionella Function: Setting Hot Water Safely explains what matters here.
Funding and when a hot water heat pump pays off
Caution is advised when it comes to funding. According to several specialist portals, a stand-alone domestic hot water heat pump is not funded on its own through KfW heating grant 458, because it does not heat any rooms. If it is installed as part of a funded heating replacement, it may be eligible as part of the measure. In that case, the application must be submitted to KfW before work begins. The legal framework also changed in 2026: since 29 July 2026, the Building Modernisation Act (GModG) has replaced the previous heating rules of the GEG and removed the 65 per cent requirement for new heating systems. BEG heating funding continues separately. Status: November 2026. Check the current conditions directly with KfW before ordering; our guide Heat Pump Funding 2026 provides more background.
The unit is particularly attractive economically if hot water has so far been produced electrically, if an old boiler only runs for hot water in summer or if there is a photovoltaic system. If the house is already heated by a heat pump that also provides hot water, the additional benefit is usually small. Bear the limits in mind too: if the intake air is cool in winter, the coefficient of performance falls and the immersion heater cuts in more often.
The unit needs little care to keep running well over the long term. The air filter in front of the evaporator should be cleaned regularly so that enough air flows through the unit, and the condensate drain must be kept clear. Many cylinders are enamelled on the inside and additionally protected against corrosion by a sacrificial anode. A specialist contractor checks its condition at the intervals specified by the manufacturer. Keeping an eye on these points ensures consistent performance for many years.
Frequently asked questions
What cylinder size do I need?
That depends on the number of people and their habits. For households of three to four people, cylinders with 250 to 300 litres are common. If in doubt, have the demand determined by a specialist contractor.
Can a domestic hot water heat pump also heat the home?
No, it is designed exclusively for producing hot water. You will still need a separate heating system for space heating.
How loud is a domestic hot water heat pump?
The fan and compressor produce an operating noise that varies depending on the model. Compare the sound power level in the data sheet and avoid placing the unit directly next to bedrooms if possible.
Does the domestic hot water heat pump cool the basement?
Yes, in recirculated air mode it cools and dehumidifies the air in the installation room. By how many degrees depends on the size of the room, the running time and other heat sources.
Conclusion
A domestic hot water heat pump produces hot water using heat from the air and needs considerably less electricity than an immersion heater to do so. It works best in a sufficiently large, unheated room with some waste heat. With a photovoltaic system, a large part of its electricity demand can be covered with your own solar power. It is worth taking a close look at funding, because as a stand-alone unit it is generally not funded through the KfW grant. You will find suitable units and accessories in our Heat Pumps and Solar Technology categories.