Nilan VPL15 and VPL28
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
Nilan VPL15 and VPL28 combines the following versions in one product: VPL15 cooling, with HMI touch panel, VPL15 Top M2, with HMI touch panel, VPL28, with HMI touch panel. Select the required version under Model and then the matching variant under Version. The details for each version are given below.
The versions in detail
The versions in detail
VPL15 cooling, with HMI touch panel: Nilan VPL15 Kühlung, m. HMI Touchpanel is a ventilation unit with heat recovery via a heat pump (active heat recovery) and cooling function. According to Nilan, the VPL15 is suitable for homes and small commercial buildings with a ventilation requirement of up to 425 m³/h. Instead of a counterflow heat exchanger, a heat pump uses the heat of the extract air. Its reversible refrigerant circuit heats the supply air in winter and cools it in summer; cooling produces condensate, which lowers the indoor humidity. According to Nilan, the cooling is not comparable to an air conditioning system. Control is via the CTS602 with HMI panel.
VPL15 Top M2, with HMI touch panel: Nilan VPL15 Top M2 mit HMI Touch Panel is a ventilation unit with heat recovery via a heat pump (active heat recovery) and cooling function. According to Nilan, the VPL15 Top M2 is suitable for homes and small commercial buildings with a ventilation requirement of up to 400 m³/h. Instead of a counterflow heat exchanger, a heat pump uses the heat of the extract air. Its reversible refrigerant circuit heats the supply air in winter and cools it in summer; cooling produces condensate, which lowers the indoor humidity. According to Nilan, the cooling is not comparable to an air conditioning system. Control is via the CTS602 with HMI panel.
VPL28, with HMI touch panel: Nilan VPL28 mit HMI Touchpanel is a ventilation unit with heat recovery via a heat pump (active heat recovery) and cooling function. According to Nilan, the VPL28 is suitable for homes and small commercial buildings, according to nilan.de especially smaller offices, shops or practices with a ventilation requirement of up to 1000 m³/h. Instead of a counterflow heat exchanger, a heat pump uses the heat of the extract air. Its reversible refrigerant circuit heats the supply air in winter and cools it in summer; cooling produces condensate, which lowers the indoor humidity. According to Nilan, the cooling is not comparable to an air conditioning system. Control is via the CTS602 with HMI panel.
Technical data
Technical data
| Housing | aluzinc sheet steel, powder-coated, white (RAL 9016) |
|---|---|
| Compressor | reciprocating compressor |
| Condensate drain | PVC, Ø 20 x 1.5 mm |
| Supply voltage | 230 V (±10%), 50/60 Hz |
| Standby power consumption | 3 W |
| Degree of protection | IP31 |
| Ambient temperature | -20 to +40 °C |
| Control | CTS602 with HMI panel |
Data per version:
| Feature | VPL15 cooling, with HMI touch panel | VPL15 Top M2, with HMI touch panel | VPL28, with HMI touch panel |
|---|---|---|---|
| Maximum airflow | up to 425 m³/h | up to 400 m³/h | up to 1000 m³/h |
| Dimensions (W x D x H) | 750 x 415 x 680 mm | 600 x 600 x 710 mm | 700 x 570 x 765 mm |
| Weight | 54 kg | 64 kg | 65 kg |
| Fans | EC, constant volume | EC, constant volume | not specified |
| Filters | ISO ePM10 > 50% (M5) / ISO ePM1 50 to 65% (F7) | EcoBlue ISO 16890 Coarse 70% (G4) | not specified |
| Duct connections | Ø 160 mm | Ø 160 mm (duct connections on top) | Ø 250 mm |
| Refrigerant | R134a, charge 1000 g | R134a, charge 650 g | R407C, charge 1.25 kg |
| Maximum power consumption / current | 720 W / 4.3 A | 720 W / 4.3 A | 2139 W / 9.3 A |
Note on variants
Note on variants
Select model and version. Not every combination is available.
| Model | Version | Item number |
|---|---|---|
| VPL15 Kühlung, mit HMI Touchpanel | Standard | 7136323 |
| VPL15 Top M2, mit HMI Touch Panel | Standard | 7333321 |
| VPL28, mit HMI Touchpanel | Standard | 71252322 |
Features
Features
- VPL15 cooling, with HMI touch panel: According to Nilan, the unit is factory-tested and supplied ready for operation and ready to plug in. Installation and commissioning must be carried out by an electrician or installer.
- VPL15 cooling, with HMI touch panel: An optional FU 15 heat pipe unit is available; according to Nilan it increases the efficiency of the heat pump in winter by up to 40% without additional power consumption.
- App control via a Nilan gateway is available as an accessory according to the data sheet.
- VPL15 cooling, with HMI touch panel: Accessories according to the data sheet: FU 15 heat pipe unit, electric reheater, water reheater, EM box, heating tape, additional board, carbon dioxide sensor, siphon, vibration dampers, sound-absorbing flexible hose, pollen filter ISO ePM1 50 to 65% (F7), gateway with app solution and HMI panel extension cable.
- VPL15 Top M2, with HMI touch panel: An optional FU 15 heat pipe unit is available; according to Nilan it increases the efficiency of the heat pump in winter by up to 40% without additional power consumption.
- VPL15 Top M2, with HMI touch panel: Accessories according to the data sheet: FU 15 heat pipe unit, electric reheater, water reheater, EM box, heating tape, additional board, carbon dioxide sensor, siphon, vibration dampers, sound-absorbing flexible hose, pollen filter ISO ePM1 50 to 65% (F7), gateway with app solution and HMI panel extension cable.
- VPL28, with HMI touch panel: According to Nilan, the unit is factory-tested and supplied ready for operation and ready to plug in. Installation and commissioning must be carried out by an electrician or installer.
- VPL28, with HMI touch panel: An optional FU 28 heat pipe unit is available; according to Nilan it increases the efficiency of the heat pump in winter by up to 40% without additional power consumption.
- VPL28, with HMI touch panel: Accessories according to the data sheet: FU 28 heat pipe unit, electric reheater, water reheater, EM box, heating tape, additional board, carbon dioxide sensor, siphon, vibration dampers, sound-absorbing flexible hose, pollen filter ISO ePM1 50 to 65% (F7), gateway with app solution and HMI panel extension cable.
Further Nilan units at a glance
- Nilan Compact S: compact unit for ventilation, heating, cooling and hot water, up to 340 m³/h according to Nilan
- Nilan Compact P2: compact unit up to 425 m³/h, also with GEO 3, GEO 6, GEO 9 ground source heat pump or AIR9 indoor part
- Nilan Combi Polar: ventilation with heat pump for heating and cooling the supply air (Combi 302 Polar, 400 Polar Top, S 302 Polar Top)
- Nilan HCR 800 T: rotary heat exchanger with heat pump for offices and schools, up to 800 m³/h
- Nilan Comfort 200 Top: flat ventilation unit for flats, up to 308 m³/h according to Nilan
- Nilan Comfort CT200 und CT500: duct connections on top, up to 500 m³/h
- Nilan Comfort 300LR: accessible from both sides, up to 400 m³/h
- Nilan Comfort 350: Top, L and R, up to 372 m³/h
- Nilan Comfort 450: with CTS602 HMI touch panel, up to 525 m³/h
- Nilan Comfort 600: up to 800 m³/h
- Nilan Comfort 1200: for schools, offices and businesses, up to 1525 m³/h
- Nilan Comfort 5000: for large buildings, up to 5300 m³/h, 3 x 400 V
- Nilan VGU250 M2: exhaust air water heater with 180 litre tank
- Nilan DHW Air9: indoor unit for hot water and space heating with the AIR9 outdoor unit
- Nilan Air9 Außenteil: outdoor unit of the AIR9 air-to-water heat pump
- Nilan Gateway LAN: control via the Nilan User App, for CTS400 and CTS602
Filters, controls and accessories are listed in the Nilan collection, all units with heat pump under Heat Pumps and all ventilation units under Ventilation Systems. The guides planning residential ventilation and heat recovery explained give background information.
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
- Data sheet VPL15 (PDF)
- User manual VPL15 (PDF)
- Installation instructions VPL15 (PDF)
- Software manual VPL15 and VPL15 Top M2 (PDF)
- Dimension drawing VPL15 (PDF)
- Wiring diagram VPL15 71363x23 (PDF)
- Data sheet VPL15 Top M2 (PDF)
- User manual VPL15 Top M2 (PDF)
- Installation instructions VPL15 Top M2 (PDF)
- Dimension drawing VPL15 Top M2 (PDF)
- Wiring diagram VPL15 Top M2 7333321 (PDF)
- Data sheet VPL28 (PDF)
- User manual VPL28 (PDF)
- Installation instructions VPL28 (PDF)
- Software manual VPL28 (PDF)
- Dimension drawing VPL28 (PDF)
- Wiring diagram VPL28 71252322 (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.