Nilan Comfort CT200 and CT500
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
Nilan Comfort CT is a series of ventilation units with heat recovery via a counterflow heat exchanger and duct connections on top. Available are the Comfort CT200 (supply air left or right) and the Comfort CT500 for a ventilation requirement of up to 500 m³/h, also as a Polar version with integrated preheater.
The versions in detail
The versions in detail
Comfort CT500: Nilan Comfort CT500 is a ventilation unit with heat recovery via a counterflow heat exchanger for large single-family houses with a ventilation requirement of up to 500 m³/h. The duct connections are located on top; according to the manufacturer, the white housing is intended for utility or technical rooms. It is controlled via the CTS602 with HMI panel. The Polar version has an integrated, steplessly controlled preheater which, according to the manufacturer, prevents ice formation in the counterflow heat exchanger: the outdoor air supplied to the unit does not fall below -3 °C, so defrosting of the heat exchanger is not necessary. An electric preheater is available as an accessory for the standard version. The unit is factory-tested and supplied ready for operation; according to the manufacturer, installation and commissioning must be carried out by a qualified electrician.
Comfort CT200: Nilan Comfort CT200 is a ventilation unit with heat recovery via a counterflow heat exchanger for homes with a ventilation requirement of up to 198 m³/h. It is designed to be installed horizontally or vertically. It is controlled via the CTS602 with HMI panel. Nilan supplies the unit tested, ready for operation and with a plug.
Technical data
Technical data
| Control | CTS602 with HMI panel |
|---|---|
| Heat exchanger | counterflow heat exchanger made of polyethylene terephthalate |
| Fans | EC, constant speed |
| Filters | EcoBlue ISO 16890 Coarse 70% (G4) |
| Condensate drain | PVC, Ø 20 x 1.5 mm |
| Supply voltage | 230 V (±10%), 50/60 Hz |
| Standby power consumption | 3.4 W |
| Degree of protection | IP31 |
| Ambient temperature | -20 to +40 °C |
| Leakage classification (EN 13141-7) | A1 |
Data per version:
| Feature | Comfort CT500 | Comfort CT200 |
|---|---|---|
| Maximum airflow | up to 500 m³/h | up to 198 m³/h |
| Housing | aluzinc sheet steel, powder-coated, white (RAL 9016) | aluzinc sheet steel |
| Duct connections | Ø 160 mm, on top | Ø 125 mm |
| Casing heat loss (EN 1886) | 0.82 W/(m²·K), class T2 | 0.96 W/(m²·K), class T2 |
| Casing sound power at 400 m³/h and 100 Pa | 48 dB(A) | not specified |
| Dimensions (W x D x H) | not specified | 1040 x 535 x 338 mm (338 mm with wall bracket) |
| Weight | not specified | 28 kg |
| Maximum power consumption / current | not specified | 70 W / 0.7 A |
| Thermal efficiency (ecodesign value) | not specified | 91.3% |
| Sound power level LWA (ecodesign value) | not specified | 49 dB(A) |
| Sound pressure level LpA at 126 m³/h and 100 Pa | not specified | 38 dB(A) |
| Specific energy consumption (SEC) class for average climate | not specified | A (scale A+ to G); SEC -41.5 kWh/(m²·a) |
Note on variants
Note on variants
Select model and version.
| Model | Version | Item number |
|---|---|---|
| Comfort CT500 | Standard | 7110520 |
| Comfort CT500 | Polar (with integrated preheater) | 7110572 |
| Comfort CT200, supply air right | Standard | 7105570 |
| Comfort CT200, supply air left | Standard | 710570 |
Features
Features
- CT500: Integrated, continuously controlled pre-heater for frost protection.
- CT500: Duct connections on top for flexible installation options within the building.
- When a filter change is due, a warning signal appears on the display.
- CT500: Filter alarm according to the joint operating instructions for CT500 and CT500 Polar; an interval of 90 days for the filter change is set at the factory.
- CT500: Accessories according to the data sheet: electric post-heater, water post-heater, EM box, DTBU damper, heating cable for frost protection of condensate drains, additional circuit board, carbon dioxide sensor, vibration dampers, siphon, sound-absorbing flexible hose, pollen filter ISO ePM1 50-65% (F7), cooker hood filter box, gateway with app solution and extension cable for HMI panel.
- CT200: Horizontal or vertical installation possible; when mounted vertically, the unit works as a top unit.
- CT200: According to the data sheet, with adaptive humidity management.
- CT200: Bypass damper in the unit.
- CT200: Panel filters in the outdoor air and extract air as standard; a pollen filter can be retrofitted for the outdoor air.
- CT200: Accessories according to the data sheet: electric pre-heater, electric post-heater, water post-heater, EM box, DTBU damper, Connection Box, CTS400 connection box, vibration dampers, siphon, sound-absorbing flexible hose, pollen filter ISO 16890 ePM1 55% (F7), cooker hood filter box, gateway with app solution, side mounting bracket and rear mounting bracket.
Further Nilan units at a glance
- Nilan Compact S: compact unit for ventilation, heating, cooling and hot water, up to 340 m³/h according to Nilan
- Nilan Compact P2: compact unit up to 425 m³/h, also with GEO 3, GEO 6, GEO 9 ground source heat pump or AIR9 indoor part
- Nilan Combi Polar: ventilation with heat pump for heating and cooling the supply air (Combi 302 Polar, 400 Polar Top, S 302 Polar Top)
- Nilan VPL15 und VPL28: active heat recovery via a reversible heat pump
- Nilan HCR 800 T: rotary heat exchanger with heat pump for offices and schools, up to 800 m³/h
- Nilan Comfort 200 Top: flat ventilation unit for flats, up to 308 m³/h according to Nilan
- Nilan Comfort 300LR: accessible from both sides, up to 400 m³/h
- Nilan Comfort 350: Top, L and R, up to 372 m³/h
- Nilan Comfort 450: with CTS602 HMI touch panel, up to 525 m³/h
- Nilan Comfort 600: up to 800 m³/h
- Nilan Comfort 1200: for schools, offices and businesses, up to 1525 m³/h
- Nilan Comfort 5000: for large buildings, up to 5300 m³/h, 3 x 400 V
- Nilan VGU250 M2: exhaust air water heater with 180 litre tank
- Nilan DHW Air9: indoor unit for hot water and space heating with the AIR9 outdoor unit
- Nilan Air9 Außenteil: outdoor unit of the AIR9 air-to-water heat pump
- Nilan Gateway LAN: control via the Nilan User App, for CTS400 and CTS602
Filters, controls and accessories are listed in the Nilan collection, all units with heat pump under Heat Pumps and all ventilation units under Ventilation Systems. The guides planning residential ventilation and heat recovery explained give background information.
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
- Data sheet Comfort CT500 (PDF)
- Product information sheet Comfort CT500 (PDF)
- User manual Comfort CT500 and CT500 Polar (PDF)
- Software manual Comfort with CTS602 Light (PDF)
- Dimension drawing Comfort CT500 (PDF)
- Wiring diagram Comfort CT500 7110520/72 (PDF)
- Data sheet Comfort CT500 Polar (PDF)
- Dimension drawing Comfort CT500 Polar (PDF)
- Data sheet Comfort CT200 with CTS602 (PDF)
- Product information sheet Comfort CT200 (PDF)
- User manual Comfort CT150/CT200 (PDF)
- Installation instructions Comfort CT150/CT200 (PDF)
- Dimension drawing Comfort CT200, supply air left (PDF)
- Dimension drawing Comfort CT200, supply air right (PDF)
- Wiring diagram Comfort CT150/CT200 71x5x70 (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.