Description
Description
S&P MBE Electric Heater Battery: electric heater battery for circular ventilation ducts, in versions B and T and B-R and T-R with integrated control. Options under version: MBE B, MBE B-R, MBE T and MBE T-R.
Technical data
Technical data
| Installation | in circular ventilation ducts, according to the manufacturer preferably on the pressure side of the fan |
|---|---|
| Housing | galvanised sheet steel, connection spigots with rubber seals |
| Control | integrated; TG-K duct sensor required as accessory |
| Nominal diameters according to data sheet | 100 to 400 mm |
| Heating elements | stainless steel |
| Safety circuit | safety thermostat B with automatic reset (60 °C) and safety thermostat C with manual reset (120 °C) |
| Terminal box | IP43 |
Data per version:
| Feature | MBE | MBE-400/90T-R |
|---|---|---|
| Air velocity | at least 1.5 m/s | at least 1.5 m/s (series data) |
| Outlet temperature | maximum +40 °C | maximum +40 °C (series data) |
| Series | not specified | MBE-R |
| Type according to S&P article list | not specified | MBE-400/90T-R |
| Nominal diameter (according to type designation) | not specified | 400 mm |
| Heating output (according to type designation) | not specified | 9.0 kW |
Note on variants
Note on variants
Select version and size. Not every combination is available.
| Version | Size | Item number | Nominal diameter | Supply | Heating output | Current | Switching stages | Min. airflow | Weight | Series | Power supply |
|---|---|---|---|---|---|---|---|---|---|---|---|
| MBE B | 100/04 | 5211800700 | 100 mm | 1~ 230 V | 0.4 kW | 1.7 A | 1 x 0.4 kW | 43 m³/h | 2.0 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 125/04 | 5211808400 | 125 mm | 1~ 230 V | 0.4 kW | 1.7 A | 1 x 0.4 kW | 67 m³/h | 2.3 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 125/08 | 5211808500 | 125 mm | 1~ 230 V | 0.8 kW | 3.5 A | 1 x 0.8 kW | 67 m³/h | 2.4 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 125/12 | 5211801500 | 125 mm | 1~ 230 V | 1.2 kW | 5.2 A | 1 x 1.2 kW | 67 m³/h | 2.5 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 160/14 | 5211808700 | 160 mm | 1~ 230 V | 1.4 kW | 6.1 A | 1 x 1.4 kW | 110 m³/h | 2.7 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 160/21 | 5211802300 | 160 mm | 1~ 230 V | 2.1 kW | 9.1 A | 1 x 2.1 kW | 110 m³/h | 3.0 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B | 200/21 | 5211808800 | 200 mm | 1~ 230 V | 2.1 kW | 9.1 A | 1 x 2.1 kW | 170 m³/h | 4.2 kg | MBE | 1~ 230 V, 50 Hz |
| MBE B-R | 100/08 | 5211781000 | 100 mm | 1~ 230 V | 0.8 kW | 3.5 A | 1 x 0.8 kW | 43 m³/h | 2.5 kg | MBE-R | 1~ 230 V, 50 Hz |
| MBE B-R | 125/12 | 5211781400 | 125 mm | 1~ 230 V | 1.2 kW | 5.2 A | 1 x 1.2 kW | 67 m³/h | 3.0 kg | MBE-R | 1~ 230 V, 50 Hz |
| MBE B-R | 160/14 | 5211781700 | 160 mm | 1~ 230 V | 1.4 kW | 6.1 A | 1 x 1.4 kW | 110 m³/h | 3.5 kg | MBE-R | 1~ 230 V, 50 Hz |
| MBE B-R | 160/21 | 5211781800 | 160 mm | 1~ 230 V | 2.1 kW | 9.1 A | 1 x 2.1 kW | 110 m³/h | 4.0 kg | MBE-R | 1~ 230 V, 50 Hz |
| MBE T | 200/50 | 5211803100 | 200 mm | 2~ 400 V | 5.0 kW | 12.5 A | 2 x 2.0 + 1 x 1.0 kW | 170 m³/h | 4.8 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 250/30 | 5211809500 | 250 mm | 2~ 400 V | 3.0 kW | 7.5 A | 1 x 2.0 + 1 x 1.0 kW | 265 m³/h | 5.0 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 250/60 | 5211804900 | 250 mm | 2~ 400 V | 6.0 kW | 15.0 A | 3 x 2.0 kW | 265 m³/h | 5.6 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 315/30 | 5211799100 | 315 mm | 2~ 400 V | 3.0 kW | 7.5 A | 1 x 3.0 kW | 420 m³/h | 6.8 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 315/60 | 5211806400 | 315 mm | 2~ 400 V | 6.0 kW | 15.0 A | 2 x 3.0 kW | 420 m³/h | 7.2 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 315/90 | 5211805600 | 315 mm | 3~ 400 V | 9.0 kW | 13.0 A | 3 x 3.0 kW | 420 m³/h | 7.4 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 355/120 | 5211807300 | 355 mm | 3~ 400 V | 12.0 kW | 17.3 A | 3 x 4.0 kW | 535 m³/h | 8.4 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 355/60 | 5211799400 | 355 mm | 2~ 400 V | 6.0 kW | 15.0 A | 2 x 3.0 kW | 535 m³/h | 8.0 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 355/90 | 5211807200 | 355 mm | 3~ 400 V | 9.0 kW | 13.0 A | 3 x 3.0 kW | 535 m³/h | 8.2 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 400/120 | 5211808000 | 400 mm | 3~ 400 V | 12.0 kW | 17.3 A | 3 x 4.0 kW | 680 m³/h | 9.5 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T | 400/90 | 5211808200 | 400 mm | 3~ 400 V | 9.0 kW | 13.0 A | 3 x 3.0 kW | 680 m³/h | 9.3 kg | MBE | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 200/20 | 5211782000 | 200 mm | 2~ 400 V | 2.0 kW | 5.0 A | 1 x 2.0 kW | 170 m³/h | 4.4 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 200/30 | 5211782100 | 200 mm | 2~ 400 V | 3.0 kW | 7.5 A | 1 x 2.0 + 1 x 1.0 kW | 170 m³/h | 4.6 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 200/50 | 5211782300 | 200 mm | 2~ 400 V | 5.0 kW | 12.5 A | 2 x 2.0 + 1 x 1.0 kW | 170 m³/h | 6.5 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 250/30 | 5211782700 | 250 mm | 2~ 400 V | 3.0 kW | 7.5 A | 1 x 2.0 + 1 x 1.0 kW | not stated | not stated | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 250/50 | 5211782900 | 250 mm | 2~ 400 V | 5.0 kW | 12.5 A | 2 x 2.0 + 1 x 1.0 kW | 265 m³/h | 6.5 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 315/30 | 5211783300 | 315 mm | 2~ 400 V | 3.0 kW | 7.5 A | 1 x 2.0 + 1 x 1.0 kW | 420 m³/h | 7.8 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 315/60 | 5211783400 | 315 mm | 2~ 400 V | 6.0 kW | 15.0 A | 3 x 2.0 kW | 420 m³/h | 7.6 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 315/90 | 5211783500 | 315 mm | 3~ 400 V | 9.0 kW | 13.0 A | 3 x 3.0 kW | 420 m³/h | 8.6 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 355/30 | 8070402409 | 355 mm | not stated | 3.0 kW | not stated | not stated | not stated | not stated | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 355/60 | 5211783800 | 355 mm | 2~ 400 V | 6.0 kW | 15.0 A | 3 x 2.0 kW | 535 m³/h | 9.3 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 355/90 | 5211783900 | 355 mm | 3~ 400 V | 9.0 kW | 13.0 A | 3 x 3.0 kW | 535 m³/h | 9.2 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 400/120 | 5211784400 | 400 mm | 3~ 400 V | 12.0 kW | 17.3 A | 3 x 4.0 kW | 680 m³/h | 11.8 kg | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 500/150 | 8070402407 | 500 mm | not stated | 15.0 kW | not stated | not stated | not stated | not stated | MBE-R | 2~ 400 V or 3~ 400 V, 50 Hz (depending on type, see table) |
| MBE T-R | 400/90 | 8070404236 | MBE-R |
Features
Features
- Integrated temperature control (control electronics in the heater); according to the wiring diagram with inputs for an external set point adjuster, a set point reduction of 4 °C, a limit sensor, an external 0 to 10 V signal and the release or run monitoring of the fan.
- Double safety circuit: in the event of overheating, the heater switches off via the safety thermostats.
- According to the manufacturer, accessories are required for operation: a TG-K duct sensor for set point detection, run monitoring of the fan (for example DS-400 differential pressure switch or a flow monitor) and a contactor circuit in the supply line (S6 A or S18 A contactor, as surface-mounted or control cabinet version).
- To protect against contamination and loss of output, S&P recommends installing an MFL air filter box.
- As further accessory, S&P lists the TG-R room sensor with set point adjustment.
- MBE: Curves for temperature rise and pressure drop, wiring diagrams and impermissible mounting positions are given in the data sheet.
- MBE-400/90T-R: According to the S&P safety note, the electrical connection must comply with DIN VDE 0100 Part 420; the heater may only be operated when the minimum airflow is reached and must switch off automatically after a safety thermostat has tripped.
- MBE-400/90T-R: Wiring diagrams for the series (MBE-___/90 T-R) are given in the data sheet and in the MBE-R operating manual.