Free shipping from 100 € within Germany
English
Account WishlistCart
S&P Deutschland GmbH  |  SKU: 5209369700

S&P CAIT PRO-REG Supply Air Unit, Electric Heating Coil

15.11649 € 21.70917 €
Tax included Shipping calculated at checkout.
● Delivery time: 5 to 10 business days
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Original manufacturer unit, CE marked
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
Request a quote

For business customers, larger quantities or projects, we will be happy to prepare a quote for you.

  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
  • Bank transfer

You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.

Description

S&P CAIT PRO-REG: Supply Air Unit, Electric Heating Coil. Available are 33 versions as well as 10 sizes as well as the orientations left and right.

Technical data

Manufacturer S&P
Coil design heating elements made of stainless steel (AISI 430), two safety thermostats (55 °C automatic reset, 85 °C manual reset), proportional control via static relay for the first stage, sequencing of the further stages
Building management Modbus RTU (RS485), BACnet TCP/IP, web server TCP/IP
Insulation mineral wool 50 mm (40 kg/m³, thermal conductivity 0.037 W/(m·K)), non-combustible (A1 according to EN 13501-1)
Operating temperature -25 to +40 °C
Control PRO-REG, integrated
S&P typeItem numberVersionSizeOrientationMax. airflowHeating outputTotal powerTotal currentWeightSeriesCoilOperating side (in supply air direction)Power supply
CAIT-48 M5 E9 PRO-REG L5209369700CAIT M5 E9 PRO-REG48left5,000 m³/h9 kW11 kW15 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E9 PRO-REG R5209364400CAIT M5 E9 PRO-REG48right5,000 m³/h9 kW11 kW15 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-48 M5 E9 PRO-REG L OI5209367000CAIT M5 E9 PRO-REG OI48left5,000 m³/h9 kW11 kW15 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E9 PRO-REG R OI5209361700CAIT M5 E9 PRO-REG OI48right5,000 m³/h9 kW11 kW15 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-48 M5 E27 PRO-REG L5209369600CAIT M5 E27 PRO-REG48left5,000 m³/h27 kW30 kW43 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E27 PRO-REG R5209364300CAIT M5 E27 PRO-REG48right5,000 m³/h27 kW30 kW43 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-48 M5 E27 PRO-REG L OI5209366900CAIT M5 E27 PRO-REG OI48left5,000 m³/h27 kW30 kW43 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E27 PRO-REG R OI5209361600CAIT M5 E27 PRO-REG OI48right5,000 m³/h27 kW30 kW43 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-88 M5 E30 PRO-REG L5209370000CAIT M5 E30 PRO-REG88left9,000 m³/h30 kW34 kW50 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E30 PRO-REG R5209364700CAIT M5 E30 PRO-REG88right9,000 m³/h30 kW34 kW50 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-88 M5 E30 PRO-REG L OI5209367300CAIT M5 E30 PRO-REG OI88left9,000 m³/h30 kW34 kW50 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E30 PRO-REG R OI5209362000CAIT M5 E30 PRO-REG OI88right9,000 m³/h30 kW34 kW50 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-48 M5 E45 PRO-REG L5209369500CAIT M5 E45 PRO-REG48left5,000 m³/h45 kW48 kW70 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E45 PRO-REG R5209364200CAIT M5 E45 PRO-REG48right5,000 m³/h45 kW48 kW70 A278 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-120 M5 E45 PRO-REG ID L5209370600CAIT M5 E45 PRO-REG ID120left12,000 m³/h45 kW53 kW78 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-120 M5 E45 PRO-REG ID R5209365300CAIT M5 E45 PRO-REG ID120right12,000 m³/h45 kW53 kW78 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-120 M5 E45 PRO-REG ID L OI5209367900CAIT M5 E45 PRO-REG ID OI120left12,000 m³/h45 kW53 kW78 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-120 M5 E45 PRO-REG ID R OI5209362600CAIT M5 E45 PRO-REG ID OI120right12,000 m³/h45 kW53 kW78 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-48 M5 E45 PRO-REG L OI5209366800CAIT M5 E45 PRO-REG OI48left5,000 m³/h45 kW48 kW70 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-48 M5 E45 PRO-REG R OI5209361500CAIT M5 E45 PRO-REG OI48right5,000 m³/h45 kW48 kW70 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-88 M5 E60 PRO-REG L5209369900CAIT M5 E60 PRO-REG88left9,000 m³/h60 kW66 kW95 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E60 PRO-REG R5209364600CAIT M5 E60 PRO-REG88right9,000 m³/h60 kW66 kW95 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-88 M5 E60 PRO-REG L OI5209367200CAIT M5 E60 PRO-REG OI88left9,000 m³/h60 kW66 kW95 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E60 PRO-REG R OI5209361900CAIT M5 E60 PRO-REG OI88right9,000 m³/h60 kW66 kW95 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-120 M5 E75 PRO-REG ID L5209370500CAIT M5 E75 PRO-REG ID120left12,000 m³/h75 kW85 kW123 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-120 M5 E75 PRO-REG ID R5209365200CAIT M5 E75 PRO-REG ID120right12,000 m³/h75 kW85 kW123 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-160 M5 E75 PRO-REG ID L5209053100CAIT M5 E75 PRO-REG ID160left16,000 m³/h75 kW80 kW116 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E75 PRO-REG ID R5209051800CAIT M5 E75 PRO-REG ID160right16,000 m³/h75 kW80 kW116 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-120 M5 E75 PRO-REG ID L OI5209367800CAIT M5 E75 PRO-REG ID OI120left12,000 m³/h75 kW85 kW123 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-120 M5 E75 PRO-REG ID R OI5209362500CAIT M5 E75 PRO-REG ID OI120right12,000 m³/h75 kW85 kW123 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-160 M5 E75 PRO-REG ID L OI5209052600CAIT M5 E75 PRO-REG ID OI160left16,000 m³/h75 kW80 kW116 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-160 M5 E75 PRO-REG ID R OI5209052200CAIT M5 E75 PRO-REG ID OI160right16,000 m³/h75 kW80 kW116 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-88 M5 E90 PRO-REG L5209369800CAIT M5 E90 PRO-REG88left9,000 m³/h90 kW97 kW141 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E90 PRO-REG R5209364500CAIT M5 E90 PRO-REG88right9,000 m³/h90 kW97 kW141 A417 kgCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-160 M5 E90 PRO-REG ID L5209053200CAIT M5 E90 PRO-REG ID160left16,000 m³/h90 kW95 kW138 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E90 PRO-REG ID R5209051900CAIT M5 E90 PRO-REG ID160right16,000 m³/h90 kW95 kW138 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E90 PRO-REG ID L5209055000CAIT M5 E90 PRO-REG ID200left20,000 m³/h90 kW101 kW146 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E90 PRO-REG ID R5209053600CAIT M5 E90 PRO-REG ID200right20,000 m³/h90 kW101 kW146 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-160 M5 E90 PRO-REG ID L OI5209052700CAIT M5 E90 PRO-REG ID OI160left16,000 m³/h90 kW95 kW138 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-160 M5 E90 PRO-REG ID R OI5209052300CAIT M5 E90 PRO-REG ID OI160right16,000 m³/h90 kW95 kW138 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-200 M5 E90 PRO-REG ID L OI5209054600CAIT M5 E90 PRO-REG ID OI200left20,000 m³/h90 kW101 kW146 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-200 M5 E90 PRO-REG ID R OI5209054100CAIT M5 E90 PRO-REG ID OI200right20,000 m³/h90 kW101 kW146 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-88 M5 E90 PRO-REG L OI5209367100CAIT M5 E90 PRO-REG OI88left9,000 m³/h90 kW97 kW141 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)left3/400 V, 50 Hz
CAIT-88 M5 E90 PRO-REG R OI5209361800CAIT M5 E90 PRO-REG OI88right9,000 m³/h90 kW97 kW141 An/aCAIT-48 to 200 PRO-REGelectric heating coil (E9, E27, E30, E45, E60, E90)right3/400 V, 50 Hz
CAIT-120 M5 E105 PRO-REG ID L5209370400CAIT M5 E105 PRO-REG ID120left12,000 m³/h105 kW116 kW169 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-120 M5 E105 PRO-REG ID R5209365100CAIT M5 E105 PRO-REG ID120right12,000 m³/h105 kW116 kW169 A696 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-120 M5 E105 PRO-REG ID L OI5209367700CAIT M5 E105 PRO-REG ID OI120left12,000 m³/h105 kW116 kW169 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)left3/400 V, 50 Hz
CAIT-120 M5 E105 PRO-REG ID R OI5209362400CAIT M5 E105 PRO-REG ID OI120right12,000 m³/h105 kW116 kW169 Anot specifiedCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105)right3/400 V, 50 Hz
CAIT-160 M5 E120 PRO-REG ID L5209052800CAIT M5 E120 PRO-REG ID160left16,000 m³/h120 kW125 kW181 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E120 PRO-REG ID R5209051600CAIT M5 E120 PRO-REG ID160right16,000 m³/h120 kW125 kW181 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E120 PRO-REG ID L5209054700CAIT M5 E120 PRO-REG ID200left20,000 m³/h120 kW131 kW189 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E120 PRO-REG ID R5209053300CAIT M5 E120 PRO-REG ID200right20,000 m³/h120 kW131 kW189 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-160 M5 E120 PRO-REG ID L OI5209052400CAIT M5 E120 PRO-REG ID OI160left16,000 m³/h120 kW125 kW181 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E120 PRO-REG ID R OI5209052000CAIT M5 E120 PRO-REG ID OI160right16,000 m³/h120 kW125 kW181 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E120 PRO-REG ID L OI5209054200CAIT M5 E120 PRO-REG ID OI200left20,000 m³/h120 kW131 kW189 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E120 PRO-REG ID R OI5209053800CAIT M5 E120 PRO-REG ID OI200right20,000 m³/h120 kW131 kW189 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)right3/400 V, 50 Hz
CAIT-160 M5 E150 PRO-REG ID L5209053000CAIT M5 E150 PRO-REG ID160left16,000 m³/h150 kW155 kW224 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E150 PRO-REG ID R5209051700CAIT M5 E150 PRO-REG ID160right16,000 m³/h150 kW155 kW224 A823 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E150 PRO-REG ID L5209054800CAIT M5 E150 PRO-REG ID200left20,000 m³/h150 kW161 kW233 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E150 PRO-REG ID R5209053400CAIT M5 E150 PRO-REG ID200right20,000 m³/h150 kW161 kW233 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-160 M5 E150 PRO-REG ID L OI5209052500CAIT M5 E150 PRO-REG ID OI160left16,000 m³/h150 kW155 kW224 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)left3/400 V, 50 Hz
CAIT-160 M5 E150 PRO-REG ID R OI5209052100CAIT M5 E150 PRO-REG ID OI160right16,000 m³/h150 kW155 kW224 A882 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E150 PRO-REG ID L OI5209054300CAIT M5 E150 PRO-REG ID OI200left20,000 m³/h150 kW161 kW233 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E150 PRO-REG ID R OI5209053900CAIT M5 E150 PRO-REG ID OI200right20,000 m³/h150 kW161 kW233 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E165 PRO-REG ID L5209054900CAIT M5 E165 PRO-REG ID200left20,000 m³/h165 kW176 kW254 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E165 PRO-REG ID R5209053500CAIT M5 E165 PRO-REG ID200right20,000 m³/h165 kW176 kW254 A1078 kgCAIT-48 to 200 PRO-REGelectric heating coil (E45, E75, E90, E105, E120, E150, E165)right3/400 V, 50 Hz
CAIT-200 M5 E165 PRO-REG ID L OI5209054400CAIT M5 E165 PRO-REG ID OI200left20,000 m³/h165 kW176 kW254 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)left3/400 V, 50 Hz
CAIT-200 M5 E165 PRO-REG ID R OI5209054000CAIT M5 E165 PRO-REG ID OI200right20,000 m³/h165 kW176 kW254 A1144 kgCAIT-48 to 200 PRO-REGelectric heating coil (E120, E150, E165)right3/400 V, 50 Hz
CAIT-10 M5 F7 E9 PRO-REG L5209381400CAIT M5 F7 E9 PRO-REG10left1,000 m³/h9 kW10 kW15 A55 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-10 M5 F7 E9 PRO-REG R5209381200CAIT M5 F7 E9 PRO-REG10right1,000 m³/h9 kW10 kW15 A55 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-20 M5 F7 E9 PRO-REG L5209381800CAIT M5 F7 E9 PRO-REG20left2,000 m³/h9 kW10 kW16 A99 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-20 M5 F7 E9 PRO-REG R5209381600CAIT M5 F7 E9 PRO-REG20right2,000 m³/h9 kW10 kW16 A99 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-30 M5 F7 E9 PRO-REG L5209382300CAIT M5 F7 E9 PRO-REG30left3,000 m³/h9 kW10 kW17 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-30 M5 F7 E9 PRO-REG R5209382100CAIT M5 F7 E9 PRO-REG30right3,000 m³/h9 kW10 kW17 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-50 M5 F7 E12 PRO-REG L5209075800CAIT M5 F7 E12 PRO-REG50left5,000 m³/h12 kW14 kW21 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-50 M5 F7 E12 PRO-REG R5209075100CAIT M5 F7 E12 PRO-REG50right5,000 m³/h12 kW14 kW21 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-20 M5 F7 E15 PRO-REG L5209381700CAIT M5 F7 E15 PRO-REG20left2,000 m³/h15 kW16 kW25 A99 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-20 M5 F7 E15 PRO-REG R5209381500CAIT M5 F7 E15 PRO-REG20right2,000 m³/h15 kW16 kW25 A99 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-30 M5 F7 E15 PRO-REG L5209382400CAIT M5 F7 E15 PRO-REG30left3,000 m³/h15 kW17 kW26 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-30 M5 F7 E15 PRO-REG R5209381900CAIT M5 F7 E15 PRO-REG30right3,000 m³/h15 kW17 kW26 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-40 M5 F7 E15 PRO-REG L5209382700CAIT M5 F7 E15 PRO-REG40left4,000 m³/h15 kW17 kW24 A112 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-40 M5 F7 E15 PRO-REG R5209382500CAIT M5 F7 E15 PRO-REG40right4,000 m³/h15 kW17 kW24 A112 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-30 M5 F7 E24 PRO-REG L5209382200CAIT M5 F7 E24 PRO-REG30left3,000 m³/h24 kW26 kW40 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-30 M5 F7 E24 PRO-REG R5209382000CAIT M5 F7 E24 PRO-REG30right3,000 m³/h24 kW26 kW40 A103 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-50 M5 F7 E24 PRO-REG L5209075900CAIT M5 F7 E24 PRO-REG50left5,000 m³/h24 kW26 kW38 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-50 M5 F7 E24 PRO-REG R5209075200CAIT M5 F7 E24 PRO-REG50right5,000 m³/h24 kW26 kW38 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-40 M5 F7 E30 PRO-REG L5209382800CAIT M5 F7 E30 PRO-REG40left4,000 m³/h30 kW33 kW47 A112 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-40 M5 F7 E30 PRO-REG R5209382600CAIT M5 F7 E30 PRO-REG40right4,000 m³/h30 kW33 kW47 A112 kgCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-50 M5 F7 E36 PRO-REG L5209076000CAIT M5 F7 E36 PRO-REG50left5,000 m³/h36 kW38 kW55 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-50 M5 F7 E36 PRO-REG R5209075300CAIT M5 F7 E36 PRO-REG50right5,000 m³/h36 kW38 kW55 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz
CAIT-50 M5 F7 E48 PRO-REG L5209076100CAIT M5 F7 E48 PRO-REG50left5,000 m³/h48 kW50 kW73 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)left3+N/400 V, 50 Hz
CAIT-50 M5 F7 E48 PRO-REG R5209075400CAIT M5 F7 E48 PRO-REG50right5,000 m³/h48 kW50 kW73 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGelectric heating coil (E9, E12, E15, E24, E30, E36, E48)right3+N/400 V, 50 Hz

Features

  • Standard according to the manufacturer: one mains connection point with maintenance switch for the entire unit, outdoor air and supply air temperature sensor, filter monitoring with indication on the display.
  • Time control (weekly and holiday program), BOOST function and ON/OFF via external signal; CAV with two-stage operation, VAV according to air quality (carbon dioxide, VOC) or relative humidity via a sensor available as an accessory, COP via a differential pressure transmitter available as an accessory.
  • Control of external motorised outdoor air shut-off dampers (24 V); optional extract air or room temperature sensor (TG-K3 PT1000 or TG-R5 PT1000).

Note on variants

The table above lists the S&P type and the item number for each option.

Data sheets and manuals (PDF)

Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.

Recommendations

From our range

Selected products from ventilation, filter and pipe technology.

View all recommendations →