S&P PURECLASS 800 CL Decentralised Ventilation Unit
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
S&P PURECLASS 800 CL: Decentralised Ventilation Unit. Available are 12 versions.
Technical data
Technical data
| Manufacturer | S&P |
|---|---|
| Airflow | 800 m³/h nominal, 1,000 m³/h maximum (boost) |
| Heat exchanger | counterflow, aluminium, EUROVENT certified according to the manufacturer |
| Heat recovery efficiency | 84.5% at nominal airflow (latent efficiency; outdoor -5 °C/80% relative humidity, indoor 20 °C/50%) |
| Bypass | standard, for free night cooling and as frost protection of the heat exchanger |
| Supply air filter | G4 (ISO Coarse 60%) + F7 (ePM1 50%) |
| Extract air filter | M5 (ePM10 50%), two-piece |
| Condensate drain | condensate pump as standard; according to the operating manual max. 12 l/h, delivery height max. 19.8 m |
| Fan power input | 365 W at 800 m³/h with saturated filters, 744 W maximum (boost, clean filters), each the sum of both fans |
| Sound pressure level | 35 dB(A) nominal, 42 dB(A) boost (3 m distance, room with acoustic ceiling, reverberation time 0.5 s, room attenuation -12 dB(A)) |
| Housing | self-supporting; double-walled side panels, white painted aluminium sheet on the outside, galvanised sheet steel on the inside; mounting brackets included |
| Insulation | melamine foam, 10 mm, sound and heat insulating, non-combustible (M1) according to the data sheet |
| Dampers | supply air damper with aluminium blades and actuator, backdraft damper on the exhaust air side |
| Series | PURECLASS 800 CL |
| Mounting | ceiling and false ceiling |
| Power supply | 1~ 230 V, 50 Hz |
| Building management | Modbus RTU (RS485) |
| S&P type | Item number | Version | Preheater | Reheater | Carbon dioxide sensor | Total current | Weight |
|---|---|---|---|---|---|---|---|
| PURECLASS 800 CL CO2 CP G4 F7 | 5153191600 | PURECLASS CL CO2 CP G4 F7 | no | no | integrated, on the extract air side | 3.20 A | 152 kg |
| PURECLASS 800 CL CP G4 F7 | 5153190400 | PURECLASS CL CP G4 F7 | no | no | not built in; compatible with external room sensors (accessory) | 3.20 A | 152 kg |
| PURECLASS 800 CL DC CO2 CP G4 F7 | 5153192000 | PURECLASS CL DC CO2 CP G4 F7 | no | hot water | integrated, on the extract air side | 3.20 A | 157 kg |
| PURECLASS 800 CL DC CP G4 F7 | 5153190800 | PURECLASS CL DC CP G4 F7 | no | hot water | not built in; compatible with external room sensors (accessory) | 3.20 A | 157 kg |
| PURECLASS 800 CL DI CO2 CP G4 F7 | 5153191800 | PURECLASS CL DI CO2 CP G4 F7 | no | electric, 3 kW | integrated, on the extract air side | 16.24 A | 158 kg |
| PURECLASS 800 CL DI CP G4 F7 | 5153190600 | PURECLASS CL DI CP G4 F7 | no | electric, 3 kW | not built in; compatible with external room sensors (accessory) | 16.24 A | 158 kg |
| PURECLASS 800 CL PH CO2 CP G4 F7 | 5153191700 | PURECLASS CL PH CO2 CP G4 F7 | electric, 2 kW | no | integrated, on the extract air side | 11.90 A | 157 kg |
| PURECLASS 800 CL PH CP G4 F7 | 5153190500 | PURECLASS CL PH CP G4 F7 | electric, 2 kW | no | not built in; compatible with external room sensors (accessory) | 11.90 A | 157 kg |
| PURECLASS 800 CL PH DC CO2 CP G4 F7 | 5153192100 | PURECLASS CL PH DC CO2 CP G4 F7 | electric, 2 kW | hot water | integrated, on the extract air side | 11.90 A | 162 kg |
| PURECLASS 800 CL PH DC CP G4 F7 | 5153190900 | PURECLASS CL PH DC CP G4 F7 | electric, 2 kW | hot water | not built in; compatible with external room sensors (accessory) | 11.90 A | 162 kg |
| PURECLASS 800 CL PH DI CO2 CP G4 F7 | 5153191900 | PURECLASS CL PH DI CO2 CP G4 F7 | electric, 2 kW | electric, 3 kW | integrated, on the extract air side | 18.40 A | 163 kg |
| PURECLASS 800 CL PH DI CP G4 F7 | 5153190700 | PURECLASS CL PH DI CP G4 F7 | electric, 2 kW | electric, 3 kW | not built in; compatible with external room sensors (accessory) | 18.40 A | 163 kg |
Features
Features
- Constant air volume (CAV) as standard via differential pressure transmitter.
- Supply air temperature control via the bypass; the bypass can also be operated manually.
- Sensors for outdoor, supply and exhaust air temperature as well as filter monitoring via pressure switches on the supply and exhaust air side.
- Monitoring of the sensors, fans, condensate pump and set values (airflow, pressure, temperature); digital output for alarm messages.
- Performance curves, acoustic data and dimensions are given in the data sheet.
Note on variants
Note on variants
The table above lists the S&P type and the item number for each option.
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.