Blauberg Helix
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
Blauberg Helix is a centrifugal fan with a scroll housing for connection to round ducts and rectangular ventilation ducts. According to the manufacturer, it is intended for supply and extract air systems in various premises and is suitable as a single component for extract or air conditioning systems. The intake flange has a round cross-section, the discharge flange a rectangular one.
The size in the model name states the diameter x width of the impeller in mm; 2E and 4E stand for a two-pole or four-pole single-phase motor.
Technical data
Technical data
| Power supply | 1 phase, 230 V, 50 Hz |
|---|---|
| Degree of protection | IPX4, motor IP44 |
| Model | Article number | Power consumption | Current consumption | Maximum airflow | Speed | Sound pressure LpA at 3 m | Medium temperature | Weight | SEC class (energy label) |
|---|---|---|---|---|---|---|---|---|---|
| Helix 140x60 2E | 8015922 | 148 W | 0.64 A | 515 m³/h | 2820 min⁻¹ | 68 dB(A) | -25 to 45 °C | 3.7 kg | C |
| Helix 160x62 2E | 8015939 | 264 W | 1.17 A | 560 m³/h | 2630 min⁻¹ | 70 dB(A) | -25 to 50 °C | 4.8 kg | C |
| Helix 160x90 2E | 8015946 | not stated | not stated | not stated | not stated | not stated | not stated | 5.1 kg | C |
| Helix 180x92 4E | 8015953 | 160 W | 0.70 A | 800 m³/h | 1465 min⁻¹ | 62 dB(A) | -25 to 45 °C | 7.1 kg | B |
| Helix 200x80 4E | 8015977 | 125 W | 0.55 A | 730 m³/h | 1430 min⁻¹ | 63 dB(A) | -25 to 45 °C | 6.8 kg | B |
| Helix 200x102 4E | 8015960 | 280 W | 1.25 A | 1350 m³/h | 1475 min⁻¹ | 65 dB(A) | -25 to 40 °C | 7.3 kg | |
| Helix 225x102 4E | 8015984 | 395 W | 1.98 A | 1480 m³/h | 1330 min⁻¹ | 69 dB(A) | -40 to 70 °C | 11.2 kg | |
| Helix 250x102 4E | 8015991 | 810 W | 3.65 A | 2000 m³/h | 1330 min⁻¹ | 63 dB(A) | -40 to 70 °C | 16.3 kg | |
| Helix 250x140 4E | 8016004 | 570 W | 2.48 A | 2000 m³/h | 1310 min⁻¹ | 60 dB(A) | -40 to 70 °C | 15.5 kg |
Features
Features
- Compact scroll housing made of steel, coated with polymer paint.
- Two-pole or four-pole asynchronous external rotor motor with forward-curved centrifugal impeller; ball bearings, designed for continuous operation; dynamically balanced motor.
- Thermal overload protection with automatic restart.
- With brackets and a mounting plate for fixing to a smooth surface.
- Mains connection via an external terminal box with sealed cable entry.
- Speed control continuously via an external thyristor controller or in steps via an external autotransformer (both available separately).
- Further accessories according to the data sheet (available separately): silencer SD, air filter box KFBT, electric heater EKH, hot water heater WKH, non-return damper VRV, shut-off damper VKA, speed controller CDT E1.8.
Note on variants
Note on variants
Select the version. The article number of each version is shown in the table above.
For Helix 160x90 2E the data sheet only states dimensions and weight, no performance data.
Notes on installation
Notes on installation
According to the data sheet, the fan can be installed as a single unit or as part of air handling chambers or air conditioning systems. The rectangular outlet duct is connected via the flange on the housing, the inlet duct via the FRZ-H connection flange. When a rectangular outlet duct is connected, the outlet opening must be covered with the SG-H protective grille. For noise and vibration damping, the SI-G rubber vibration dampers are fitted in the openings of the mounting plate. Flange, grille and vibration dampers are available separately; matching types according to the data sheet:
| Model | Vibration damper | Connection flange | Protective grille |
|---|---|---|---|
| Helix 140x60 2E | SI-G 8 | FRZ-H 140 | SG-H 140 |
| Helix 160x62 2E | SI-G 8 | FRZ-H 160 | SG-H 160 |
| Helix 160x90 2E | SI-G 8 | FRZ-H 160 | SG-H 160 |
| Helix 180x92 4E | SI-G 8 | FRZ-H 180 | SG-H 180 |
| Helix 200x80 4E | SI-G 8 | FRZ-H 200 | SG-H 200 |
| Helix 200x102 4E | SI-G 8 | FRZ-H 200 | SG-H 200 |
| Helix 225x102 4E | SI-G 16 | FRZ-H 225 | SG-H 225 |
| Helix 250x102 4E | SI-G 16 | FRZ-H 250 | SG-H 250 |
| Helix 250x140 4E | SI-G 16 | FRZ-H 250 | SG-H 250 |
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.
From our range
Selected products from ventilation, filter and pipe technology.