Description

S&P IBW Warmwasser-Heizregister, Baugröße 200 bis 450 is a hot water heater for installation in rectangular ventilation ducts from the S&P IBW series. According to the manufacturer, the galvanised sheet steel housing with 20 mm standard flange fits the S&P duct fans; the air heater consists of aluminium fins pressed onto copper tubes.

According to the manufacturer, the heater should be installed on the pressure side of the fan. For each size, the types are available in a version with lower and one with higher heating output (suffix -2 or -3 or -4).

Technical data

SeriesIBW
Installationin rectangular ventilation ducts, according to the manufacturer preferably on the pressure side of the fan
Housinggalvanised sheet steel, 20 mm standard flange
Heat exchangeraluminium fins pressed onto copper tubes
Operating pressuremax. 16 bar
Operating temperaturemax. 150 °C
Reference values of the tableoutdoor air 0 °C; flow/return 80/60 °C or 60/40 °C
ModelArticle numberDuct connection W x HHeating output 80/60Heating output 60/40Temperature rise 80/60Temperature rise 60/40AirflowWater pressure drop 80/60Water flow 80/60WeightConnectionPump hot water control (accessory)
IBW-200-25132838400400 x 200 mm10.7 kW6.5 kW28 K16 K1,150 m³/h2 kPa470 l/h8.0 kg3/4"PWW-N1
IBW-200-45132838500400 x 200 mm17.3 kW10.8 kW44 K27 K1,150 m³/h3 kPa760 l/h9.6 kg3/4"PWW-N1
IBW-225-25132838600500 x 250 mm17.1 kW10.8 kW28 K17 K1,800 m³/h6 kPa750 l/h8.8 kg3/4"PWW-N1
IBW-225-45132838700500 x 250 mm29.7 kW19.8 kW48 K33 K1,800 m³/h8 kPa1,300 l/h10.9 kg3/4"PWW-N1
IBW-250-25132838800500 x 300 mm21.6 kW13.7 kW29 K18 K2,160 m³/h4 kPa950 l/h12.2 kg3/4"PWW-N1
IBW-250-45132838900500 x 300 mm35.9 kW24.2 kW48 K33 K2,160 m³/h10 kPa1,580 l/h11.8 kg1"PWW-N1
IBW-285-25132839000600 x 300 mm25.7 kW16.2 kW28 K18 K2,600 m³/h4 kPa1,130 l/h13.1 kg3/4"PWW-N1
IBW-285-45132839100600 x 300 mm43.4 kW29.4 kW47 K31 K2,600 m³/h10 kPa1,900 l/h14.7 kg1"PWW-N2
IBW-315-25132839200600 x 350 mm28.5 kW18.1 kW26 K18 K3,020 m³/h6 kPa1,250 l/h14.1 kg3/4"PWW-N1
IBW-315-45132839300600 x 350 mm48.2 kW32.5 kW46 K31 K3,020 m³/h13 kPa2,120 l/h14.6 kg1"PWW-N2
IBW-355-25132839400700 x 400 mm40.7 kW26.0 kW30 K18 K4,030 m³/h5 kPa1,790 l/h14.6 kg1"PWW-N1
IBW-355-35132839500700 x 400 mm55.0 kW36.0 kW40 K26 K4,030 m³/h6 kPa2,410 l/h16.5 kg1"PWW-N2
IBW-400-25132839600800 x 500 mm59.1 kW38.1 kW31 K18 K5,760 m³/h7 kPa2,600 l/h18.2 kg1"PWW-N2
IBW-400-45132839700800 x 500 mm96.3 kW65.1 kW42 K27 K5,760 m³/h10 kPa4,230 l/h24.8 kg1"not stated
IBW-450-251328398001000 x 500 mm75.1 kW49.0 kW30 K20 K7,200 m³/h7 kPa3,300 l/h20.3 kg1"not stated
IBW-450-451328399001000 x 500 mm122.0 kW82.6 kW42 K28 K7,200 m³/h14 kPa5,370 l/h28.2 kg1"not stated

Features

  • According to the manufacturer, screw connections must be provided for the water connection; the heater must be able to be drained and vented during installation.
  • According to the S&P safety note, a frost protection device must be provided which switches off the fan and, if necessary, closes a damper in the outdoor air if the air or return temperature is too low.
  • To protect against contamination and loss of output, S&P recommends installing an air filter box.
  • As accessories, S&P lists the PWW-N1 and PWW-N2 pump hot water controls (hydraulic unit with circulation pump, three-way mixer with 230 V actuator, shut-off valves and LHCC supply air temperature control); the matching unit for each type is shown in the table.
  • Curves for temperature rise and pressure drop and the dimension drawing are given in the data sheet.

Note on variants

The "Model" selection shows the S&P type: the number after IBW is the size matching the duct connection in the table; the suffix -2, -3 or -4 distinguishes the output levels within a size. For IBW-400-4, IBW-450-2 and IBW-450-4, the data sheet does not list a matching pump hot water control.