S&P IBE T Electric Heating Coil
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Expert advice from building services specialists
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Invoice with VAT shown separately
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
S&P IBE T is an electric heater for installation in rectangular ventilation ducts from the S&P IBE series. According to the manufacturer, the galvanised sheet steel housing with 20 mm standard flange fits the S&P duct fans; the heating elements are made of stainless steel. Available are the sizes 200/9, 225/16,5, 250/16,5, 285/20, 315/30, 355/30 and 400/50.
According to the manufacturer, the heater should be installed on the pressure side of the fan; the air velocity must be at least 2 m/s, the outlet temperature at most +40 °C. Operation requires a power controller, a duct sensor and fan run monitoring as accessories.
Technical data
Technical data
| Manufacturer | S&P |
|---|---|
| Installation | in rectangular ventilation ducts, according to the manufacturer preferably on the pressure side of the fan |
| Housing | galvanised sheet steel, 20 mm standard flange |
| Safety circuit | safety thermostat B with automatic reset (60 °C) and safety thermostat C with manual reset (120 °C) |
| Series | IBE |
| Heating elements | stainless steel |
| Power supply | 3~ 400 V, 50 Hz |
| Terminal box | IP43 |
| Air velocity | at least 2 m/s |
| Outlet temperature | maximum +40 °C |
| Length | 370 mm |
| S&P type | Item number | Size | Duct connection W x H | Heating output | Current | Switching stages | Min. airflow | Weight | Controller (accessory) | Number of contactors |
|---|---|---|---|---|---|---|---|---|---|---|
| IBE-200/9 T | 5132831800 | 200/9 | 400 x 200 mm | 9.0 kW | 13.0 A | 3 x 3.0 kW | 435 m³/h | 10.4 kg | TTC-2000 | 1 |
| IBE-225/16,5 T | 5132832600 | 225/16,5 | 500 x 250 mm | 16.7 kW | 24.1 A | 3 x 5.6 kW | 680 m³/h | 14.5 kg | TTC-2000 | 1 |
| IBE-250/16,5 T | 5132833400 | 250/16,5 | 500 x 300 mm | 16.7 kW | 24.1 A | 3 x 5.6 kW | 820 m³/h | 15.5 kg | TTC-2000 | 1 |
| IBE-285/20 T | 5132834200 | 285/20 | 600 x 300 mm | 20.0 kW | 28.9 A | 3 x 6.7 kW | 980 m³/h | 19.5 kg | TTC-40 | 1 |
| IBE-315/30 T | 5132835900 | 315/30 | 600 x 350 mm | 30.0 kW | 43.4 A | 4 x 7.5 kW | 1,140 m³/h | 21.0 kg | TTC-2000 + TT-S1 | 2 |
| IBE-355/30 T | 5132836700 | 355/30 | 700 x 400 mm | 30.0 kW | 43.4 A | 4 x 7.5 kW | 1,520 m³/h | 23.3 kg | TTC-2000 + TT-S1 | 2 |
| IBE-400/50 T | 5132837500 | 400/50 | 800 x 500 mm | 50.0 kW | 72.3 A | 3 x 16.7 kW | 2,170 m³/h | 27.0 kg | TTC-40 + TT-S4 | 3 |
Features
Features
- Double safety circuit: in the event of overheating, the heater switches off via the safety thermostats.
- According to the manufacturer, accessories are required for operation: a power controller (TTC-2000, TTC-2000 + TT-S1, TTC-40, TTC-40 + TT-S4), a TG-K duct sensor for set point detection, run monitoring of the fan (for example DS-500 differential pressure switch or a flow monitor) and contactors in the supply line (number see table).
- According to the S&P safety note, the electrical connection must comply with DIN VDE 0100 Part 420; the heater may only be operated when the minimum airflow is reached and must switch off automatically after a safety thermostat has tripped.
- To protect against contamination and loss of output, S&P recommends installing an IFL air filter box.
- Curves for temperature rise and pressure drop, dimension drawing, wiring diagrams and impermissible mounting positions are given in the data sheet.
- According to the manufacturer, accessories are required for operation: a power controller (TTC-2000), a TG-K duct sensor for set point detection, run monitoring of the fan (for example DS-500 differential pressure switch or a flow monitor) and contactors in the supply line (number see table).
Note on variants
Note on variants
The table above lists the S&P type and the item number for each option.
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.
From our range
Selected products from ventilation, filter and pipe technology.