Free shipping from 100 € within Germany
English
Account WishlistCart
S&P Deutschland GmbH  |  SKU: L012800085

S&P CAIT PRO-REG Supply Air Unit, Electric Heating Coil and Direct Expansion Evaporator

16.99349 € 19.22949 €
Tax included Shipping calculated at checkout.
● Delivery time: 5 to 10 business days
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Original manufacturer unit, CE marked
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
Request a quote

For business customers, larger quantities or projects, we will be happy to prepare a quote for you.

  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
  • Bank transfer

You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.

Description

S&P CAIT PRO-REG: Supply Air Unit, Electric Heating Coil and Direct Expansion Evaporator. Available are the versions CAIT M5 E18 X3 PRO-REG, CAIT M5 E18 X3 PRO-REG OI, CAIT M5 E30 X3 PRO-REG, CAIT M5 E30 X3 PRO-REG OI, CAIT M5 E36 X3 PRO-REG, CAIT M5 E36 X3 PRO-REG OI, CAIT M5 E60 X3 PRO-REG and CAIT M5 E60 X3 PRO-REG OI as well as the sizes 48 and 88 as well as the orientations left and right.

Technical data

Manufacturer S&P
Coil design electric pre-heater inside the unit upstream of the evaporator; direct expansion evaporator with aluminium fins on copper tubes, threaded connections, condensate tray and droplet separator made of stainless steel; control of the evaporator circuit including valves and sensors is provided by an on-site DX unit
Louvre damper not integrated, motorised damper available as an accessory
Filters M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory
Fan plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
Housing self-supporting, double-walled; outer coating with corrosion resistance class RC3 and UV resistance class RUV3 according to EN 10169 in RAL 7024; inner walls made of galvanised sheet steel
Insulation mineral wool 50 mm (40 kg/m³, thermal conductivity 0.037 W/(m·K)), non-combustible (A1 according to EN 13501-1)
Operation ETD touch display, 10 m cable with RJ10 plug (maximum 50 m)
Building management Modbus RTU (RS485), BACnet TCP/IP, web server TCP/IP
Series CAIT-48 to 200 PRO-REG
Coil electric pre-heater and direct expansion evaporator module (E18 X3, E30 X3, E36 X3, E60 X3)
Power supply 3/400 V, 50 Hz
Motor protection IP54, insulation class B (size 48), F (from 88)
Operating temperature -25 to +40 °C
Delivery form sizes 48 and 88 as a compact unit
Base size 48 on powder-coated feet; size 88 on transverse mounting rails
Control PRO-REG, integrated
S&P typeItem numberVersionSizeOrientationMax. airflowPre-heater outputTotal powerTotal currentRefrigerant connection liquid/gasCooling capacity²Dimensions¹Operating side (in supply air direction)Installation
CAIT-48 M5 E18 X3 PRO-REG LL012800085CAIT M5 E18 X3 PRO-REG48left5,000 m³/h18 kW21 kW28 A3/8" / 3/4"29 kW1715 x 1000 x 800 mmleftindoor (without rain roof)
CAIT-48 M5 E18 X3 PRO-REG RL012800089CAIT M5 E18 X3 PRO-REG48right5,000 m³/h18 kW21 kW28 A3/8" / 3/4"29 kW1715 x 1000 x 800 mmrightindoor (without rain roof)
CAIT-48 M5 E18 X3 PRO-REG L OIL012800092CAIT M5 E18 X3 PRO-REG OI48left5,000 m³/h18 kW21 kW28 A3/8" / 3/4"29 kW1975 x 1175 x 1020 mmleftoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-48 M5 E18 X3 PRO-REG R OIL012800088CAIT M5 E18 X3 PRO-REG OI48right5,000 m³/h18 kW21 kW28 A3/8" / 3/4"29 kW1975 x 1175 x 1020 mmrightoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-88 M5 E30 X3 PRO-REG LL012800087CAIT M5 E30 X3 PRO-REG88left9,000 m³/h30 kW36 kW48 A2 x 3/8" / 3/4"49 kW1950 x 1315 x 1100 mmleftindoor (without rain roof)
CAIT-88 M5 E30 X3 PRO-REG RL012800091CAIT M5 E30 X3 PRO-REG88right9,000 m³/h30 kW36 kW48 A2 x 3/8" / 3/4"49 kW1950 x 1315 x 1100 mmrightindoor (without rain roof)
CAIT-88 M5 E30 X3 PRO-REG L OIL012800086CAIT M5 E30 X3 PRO-REG OI88left9,000 m³/h30 kW36 kW48 A2 x 3/8" / 3/4"49 kW2210 x 1485 x 1270 mmleftoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-88 M5 E30 X3 PRO-REG R OIL012800090CAIT M5 E30 X3 PRO-REG OI88right9,000 m³/h30 kW36 kW48 A2 x 3/8" / 3/4"49 kW2210 x 1485 x 1270 mmrightoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-48 M5 E36 X3 PRO-REG L5209055500CAIT M5 E36 X3 PRO-REG48left5,000 m³/h36 kW39 kW54 A3/8" / 3/4"29 kW1715 x 1000 x 800 mmleftindoor (without rain roof)
CAIT-48 M5 E36 X3 PRO-REG R5209055100CAIT M5 E36 X3 PRO-REG48right5,000 m³/h36 kW39 kW54 A3/8" / 3/4"29 kW1715 x 1000 x 800 mmrightindoor (without rain roof)
CAIT-48 M5 E36 X3 PRO-REG L OI5209055400CAIT M5 E36 X3 PRO-REG OI48left5,000 m³/h36 kW39 kW54 A3/8" / 3/4"29 kW1975 x 1175 x 1020 mmleftoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-48 M5 E36 X3 PRO-REG R OI5209055300CAIT M5 E36 X3 PRO-REG OI48right5,000 m³/h36 kW39 kW54 A3/8" / 3/4"29 kW1975 x 1175 x 1020 mmrightoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-88 M5 E60 X3 PRO-REG L5209055900CAIT M5 E60 X3 PRO-REG88left9,000 m³/h60 kW66 kW91 A2 x 3/8" / 3/4"49 kW1950 x 1315 x 1100 mmleftindoor (without rain roof)
CAIT-88 M5 E60 X3 PRO-REG R5209055600CAIT M5 E60 X3 PRO-REG88right9,000 m³/h60 kW66 kW91 A2 x 3/8" / 3/4"49 kW1950 x 1315 x 1100 mmrightindoor (without rain roof)
CAIT-88 M5 E60 X3 PRO-REG L OI5209055800CAIT M5 E60 X3 PRO-REG OI88left9,000 m³/h60 kW66 kW91 A2 x 3/8" / 3/4"49 kW2210 x 1485 x 1270 mmleftoutdoor installation possible, factory-fitted weather protection roof (OI)
CAIT-88 M5 E60 X3 PRO-REG R OI5209055700CAIT M5 E60 X3 PRO-REG OI88right9,000 m³/h60 kW66 kW91 A2 x 3/8" / 3/4"49 kW2210 x 1485 x 1270 mmrightoutdoor installation possible, factory-fitted weather protection roof (OI)

¹ Dimensions according to dimension drawing A x B x C, for OI versions with protective roof N x O x P. ² Maximum possible cooling capacity of the evaporator according to the data sheet with refrigerant R-410a at outdoor air 32 °C and 50% relative humidity (airflow 4,800 m³/h for size 48, 8,800 m³/h for size 88).

Features

  • Time control (weekly and holiday program), BOOST function and ON/OFF via external signal; CAV with two-stage operation, VAV according to air quality (carbon dioxide, VOC) or relative humidity via a sensor available as an accessory.
  • Set point monitoring (airflow, pressure, temperature), fan run monitoring, sensor function monitoring, alarm memory for the last 40 messages and potential-free contact, e.g. for shutdown in case of fire alarm.

Note on variants

The table above lists the S&P type and the item number for each option.

Data sheets and manuals (PDF)

Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.

Recommendations

From our range

Selected products from ventilation, filter and pipe technology.

View all recommendations →