S&P CAIT PRO-REG Supply Air Unit, Hot Water Heating Coil
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
S&P CAIT PRO-REG: Supply Air Unit, Hot Water Heating Coil. Available are the versions CAIT M5 F7 H2 PRO-REG, CAIT M5 F7 H3 PRO-REG, CAIT M5 H2 PRO-REG ID, CAIT M5 H2 PRO-REG ID OI, CAIT M5 H3 PRO-REG and CAIT M5 H3 PRO-REG OI as well as the sizes 50, 40, 120, 160, 200, 48 and 88 as well as the orientations left and right.
Technical data
Technical data
| Manufacturer | S&P |
|---|---|
| Building management | Modbus RTU (RS485), BACnet TCP/IP, web server TCP/IP |
| Insulation | mineral wool 50 mm (40 kg/m³, thermal conductivity 0.037 W/(m·K)), non-combustible (A1 according to EN 13501-1) |
| Operating temperature | -25 to +40 °C |
| Control | PRO-REG, integrated |
| S&P type | Item number | Version | Size | Orientation | Max. airflow | Total current | Weight | Series | Coil | Coil design | Operating side (in supply air direction) | Power supply | Filters |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CAIT-50 M5 F7 H2 PRO-REG L | 5209076200 | CAIT M5 F7 H2 PRO-REG | 50 | left | 5,000 m³/h | 3 A | see data sheet | CAIB/CAIT-10 to 50 PRO-REG | hot water heating coil (H2, H3) | 3 rows, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each |
| CAIT-50 M5 F7 H2 PRO-REG R | 5209075500 | CAIT M5 F7 H2 PRO-REG | 50 | right | 5,000 m³/h | 3 A | see data sheet | CAIB/CAIT-10 to 50 PRO-REG | hot water heating coil (H2, H3) | 3 rows, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each |
| CAIT-40 M5 F7 H3 PRO-REG L | 5209379600 | CAIT M5 F7 H3 PRO-REG | 40 | left | 4,000 m³/h | 2 A | 121 kg | CAIB/CAIT-10 to 50 PRO-REG | hot water heating coil (H2, H3) | 3 rows, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each |
| CAIT-40 M5 F7 H3 PRO-REG R | 5209379500 | CAIT M5 F7 H3 PRO-REG | 40 | right | 4,000 m³/h | 2 A | 121 kg | CAIB/CAIT-10 to 50 PRO-REG | hot water heating coil (H2, H3) | 3 rows, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each |
| CAIT-120 M5 H2 PRO-REG ID L | 5209370900 | CAIT M5 H2 PRO-REG ID | 120 | left | 12,000 m³/h | 9 A | 583 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-120 M5 H2 PRO-REG ID R | 5209365600 | CAIT M5 H2 PRO-REG ID | 120 | right | 12,000 m³/h | 9 A | 583 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-160 M5 H2 PRO-REG ID L | 5209048800 | CAIT M5 H2 PRO-REG ID | 160 | left | 16,000 m³/h | 8 A | 758 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-160 M5 H2 PRO-REG ID R | 5209048400 | CAIT M5 H2 PRO-REG ID | 160 | right | 16,000 m³/h | 8 A | 758 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-200 M5 H2 PRO-REG ID L | 5209049200 | CAIT M5 H2 PRO-REG ID | 200 | left | 20,000 m³/h | 16 A | 995 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-200 M5 H2 PRO-REG ID R | 5209048900 | CAIT M5 H2 PRO-REG ID | 200 | right | 20,000 m³/h | 16 A | 995 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-120 M5 H2 PRO-REG ID L OI | 5209368200 | CAIT M5 H2 PRO-REG ID OI | 120 | left | n/a | 9 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-120 M5 H2 PRO-REG ID R OI | 5209362900 | CAIT M5 H2 PRO-REG ID OI | 120 | right | n/a | 9 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-160 M5 H2 PRO-REG ID L OI | 5209048600 | CAIT M5 H2 PRO-REG ID OI | 160 | left | n/a | 8 A | 815 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-160 M5 H2 PRO-REG ID R OI | 5209048500 | CAIT M5 H2 PRO-REG ID OI | 160 | right | n/a | 8 A | 815 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-200 M5 H2 PRO-REG ID L OI | 5209049100 | CAIT M5 H2 PRO-REG ID OI | 200 | left | n/a | 16 A | 1061 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-200 M5 H2 PRO-REG ID R OI | 5209049000 | CAIT M5 H2 PRO-REG ID OI | 200 | right | n/a | 16 A | 1061 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H2) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-48 M5 H3 PRO-REG L | 5209370700 | CAIT M5 H3 PRO-REG | 48 | left | 5,000 m³/h | 2 A | 233 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-48 M5 H3 PRO-REG R | 5209365400 | CAIT M5 H3 PRO-REG | 48 | right | 5,000 m³/h | 2 A | 233 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-88 M5 H3 PRO-REG L | 5209370800 | CAIT M5 H3 PRO-REG | 88 | left | 9,000 m³/h | 4.5 A | 350 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-88 M5 H3 PRO-REG R | 5209365500 | CAIT M5 H3 PRO-REG | 88 | right | 9,000 m³/h | 4.5 A | 350 kg | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-48 M5 H3 PRO-REG L OI | 5209368000 | CAIT M5 H3 PRO-REG OI | 48 | left | 5,000 m³/h | 2 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-48 M5 H3 PRO-REG R OI | 5209362700 | CAIT M5 H3 PRO-REG OI | 48 | right | 5,000 m³/h | 2 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-88 M5 H3 PRO-REG L OI | 5209368100 | CAIT M5 H3 PRO-REG OI | 88 | left | 9,000 m³/h | 4.5 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
| CAIT-88 M5 H3 PRO-REG R OI | 5209362800 | CAIT M5 H3 PRO-REG OI | 88 | right | 9,000 m³/h | 4.5 A | not specified | CAIT-48 to 200 PRO-REG | hot water heating coil (H3) | 2, 3, 4, 6 or 8 rows depending on the model, aluminium fins on copper tubes, threaded connections, frost protection via contact sensor | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory |
Features
Features
- Water coils mounted on a slide rail, accessible via the side panels.
- Scope of delivery according to the manufacturer: unit with control and ETD touch display (10 m cable).
Note on variants
Note on variants
The table above lists the S&P type and the item number for each option.
Data sheets and manuals (PDF)
Data sheets and manuals (PDF)
Ask about this product
We usually reply within one business day.
Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.
From our range
Selected products from ventilation, filter and pipe technology.