Free shipping from 100 € within Germany
English
Account WishlistCart
S&P Deutschland GmbH  |  SKU: 5209076400

S&P CAIT PRO-REG Supply Air Unit, Hot Water and Chilled Water Coils

12.77249 € 18.33671 €
Tax included Shipping calculated at checkout.
● Delivery time: 5 to 10 business days
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Original manufacturer unit, CE marked
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
Request a quote

For business customers, larger quantities or projects, we will be happy to prepare a quote for you.

  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
  • Bank transfer

You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.

Description

S&P CAIT PRO-REG: Supply Air Unit, Hot Water and Chilled Water Coils. Available are the versions CAIT M5 F7 H2 C4 PRO-REG, CAIT M5 F7 H3 C4 PRO-REG, CAIT M5 H2 C3 PRO-REG ID, CAIT M5 H2 C3 PRO-REG ID OI, CAIT M5 H2 C4 PRO-REG ID, CAIT M5 H2 C4 PRO-REG ID OI, CAIT M5 H3 C4 PRO-REG and CAIT M5 H3 C4 PRO-REG OI as well as the sizes 40, 48, 50, 88, 120, 160 and 200 as well as the orientations left and right.

Technical data

Manufacturer S&P
Coil design heating coil with frost protection via contact sensor; cooling coil with condensate tray and droplet separator made of stainless steel; aluminium fins on copper tubes, threaded connections
Building management Modbus RTU (RS485), BACnet TCP/IP, web server TCP/IP
Insulation mineral wool 50 mm (40 kg/m³, thermal conductivity 0.037 W/(m·K)), non-combustible (A1 according to EN 13501-1)
Operating temperature -25 to +40 °C
Control PRO-REG, integrated
S&P typeItem numberVersionSizeOrientationMax. airflowTotal currentWeightSeriesCoilOperating side (in supply air direction)Power supplyFiltersFan
CAIT-50 M5 F7 H2 C4 PRO-REG L5209076400CAIT M5 F7 H2 C4 PRO-REG50left5,000 m³/h3 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGseparate hot water and chilled water coils (H2 C4, H3 C4)left3+N/400 V, 50 HzM5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm eachplug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B
CAIT-50 M5 F7 H2 C4 PRO-REG R5209075700CAIT M5 F7 H2 C4 PRO-REG50right5,000 m³/h3 Asee data sheetCAIB/CAIT-10 to 50 PRO-REGseparate hot water and chilled water coils (H2 C4, H3 C4)right3+N/400 V, 50 HzM5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm eachplug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B
CAIT-40 M5 F7 H3 C4 PRO-REG L5209380200CAIT M5 F7 H3 C4 PRO-REG40left4,000 m³/h2 A140 kgCAIB/CAIT-10 to 50 PRO-REGseparate hot water and chilled water coils (H2 C4, H3 C4)left3+N/400 V, 50 HzM5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm eachplug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B
CAIT-40 M5 F7 H3 C4 PRO-REG R5209380100CAIT M5 F7 H3 C4 PRO-REG40right4,000 m³/h2 A140 kgCAIB/CAIT-10 to 50 PRO-REGseparate hot water and chilled water coils (H2 C4, H3 C4)right3+N/400 V, 50 HzM5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm eachplug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B
CAIT-120 M5 H2 C3 PRO-REG ID L5209371800CAIT M5 H2 C3 PRO-REG ID120left12,000 m³/h9 A646 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-120 M5 H2 C3 PRO-REG ID R5209366400CAIT M5 H2 C3 PRO-REG ID120right12,000 m³/h9 A646 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-120 M5 H2 C3 PRO-REG ID L OI5209369100CAIT M5 H2 C3 PRO-REG ID OI120left12,000 m³/h9 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-120 M5 H2 C3 PRO-REG ID R OI5209363800CAIT M5 H2 C3 PRO-REG ID OI120right12,000 m³/h9 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-160 M5 H2 C4 PRO-REG ID L5209049800CAIT M5 H2 C4 PRO-REG ID160left16,000 m³/h8 A939 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-160 M5 H2 C4 PRO-REG ID R5209049300CAIT M5 H2 C4 PRO-REG ID160right16,000 m³/h8 A939 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-200 M5 H2 C4 PRO-REG ID L5209050200CAIT M5 H2 C4 PRO-REG ID200left20,000 m³/h16 A1118 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-200 M5 H2 C4 PRO-REG ID R5209049900CAIT M5 H2 C4 PRO-REG ID200right20,000 m³/h16 A1118 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H2 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-160 M5 H2 C4 PRO-REG ID L OI5209049600CAIT M5 H2 C4 PRO-REG ID OI160left16,000 m³/h8 A996 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-160 M5 H2 C4 PRO-REG ID R OI5209049400CAIT M5 H2 C4 PRO-REG ID OI160right16,000 m³/h8 A996 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-200 M5 H2 C4 PRO-REG ID L OI5209050100CAIT M5 H2 C4 PRO-REG ID OI200left20,000 m³/h16 A1184 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-200 M5 H2 C4 PRO-REG ID R OI5209050000CAIT M5 H2 C4 PRO-REG ID OI200right20,000 m³/h16 A1184 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-48 M5 H3 C4 PRO-REG L5209371600CAIT M5 H3 C4 PRO-REG48left5,000 m³/h2 A258 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H3 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-48 M5 H3 C4 PRO-REG R5209366200CAIT M5 H3 C4 PRO-REG48right5,000 m³/h2 A258 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H3 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-88 M5 H3 C4 PRO-REG L5209371700CAIT M5 H3 C4 PRO-REG88left9,000 m³/h4.5 A387 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H3 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-88 M5 H3 C4 PRO-REG R5209366300CAIT M5 H3 C4 PRO-REG88right9,000 m³/h4.5 A387 kgCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H3 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-48 M5 H3 C4 PRO-REG L OI5209368900CAIT M5 H3 C4 PRO-REG OI48left5,000 m³/h2 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-48 M5 H3 C4 PRO-REG R OI5209363600CAIT M5 H3 C4 PRO-REG OI48right5,000 m³/h2 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-88 M5 H3 C4 PRO-REG L OI5209369000CAIT M5 H3 C4 PRO-REG OI88left9,000 m³/h4.5 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)left3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics
CAIT-88 M5 H3 C4 PRO-REG R OI5209363700CAIT M5 H3 C4 PRO-REG OI88right9,000 m³/h4.5 An/aCAIT-48 to 200 PRO-REGseparate hot water and chilled water coils (H2 C3, H3 C4)right3/400 V, 50 HzM5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessoryplug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics

Features

  • Water coils mounted on a slide rail, accessible via the side panels.
  • Scope of delivery according to the manufacturer: unit with control and ETD touch display (10 m cable).

Note on variants

The table above lists the S&P type and the item number for each option.

Data sheets and manuals (PDF)