S&P CAIT PRO-REG Supply Air Unit, Hot Water and Chilled Water Coils
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
For business customers, larger quantities or projects, we will be happy to prepare a quote for you.
The price for this version is available on request. We will be happy to send you a quote.
You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.
Description
Description
S&P CAIT PRO-REG: Supply Air Unit, Hot Water and Chilled Water Coils. Available are the versions CAIT M5 F7 H2 C4 PRO-REG, CAIT M5 F7 H3 C4 PRO-REG, CAIT M5 H2 C3 PRO-REG ID, CAIT M5 H2 C3 PRO-REG ID OI, CAIT M5 H2 C4 PRO-REG ID, CAIT M5 H2 C4 PRO-REG ID OI, CAIT M5 H3 C4 PRO-REG and CAIT M5 H3 C4 PRO-REG OI as well as the sizes 40, 48, 50, 88, 120, 160 and 200 as well as the orientations left and right.
Technical data
Technical data
| Manufacturer | S&P |
|---|---|
| Coil design | heating coil with frost protection via contact sensor; cooling coil with condensate tray and droplet separator made of stainless steel; aluminium fins on copper tubes, threaded connections |
| Building management | Modbus RTU (RS485), BACnet TCP/IP, web server TCP/IP |
| Insulation | mineral wool 50 mm (40 kg/m³, thermal conductivity 0.037 W/(m·K)), non-combustible (A1 according to EN 13501-1) |
| Operating temperature | -25 to +40 °C |
| Control | PRO-REG, integrated |
| S&P type | Item number | Version | Size | Orientation | Max. airflow | Total current | Weight | Series | Coil | Operating side (in supply air direction) | Power supply | Filters | Fan |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CAIT-50 M5 F7 H2 C4 PRO-REG L | 5209076400 | CAIT M5 F7 H2 C4 PRO-REG | 50 | left | 5,000 m³/h | 3 A | see data sheet | CAIB/CAIT-10 to 50 PRO-REG | separate hot water and chilled water coils (H2 C4, H3 C4) | left | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B |
| CAIT-50 M5 F7 H2 C4 PRO-REG R | 5209075700 | CAIT M5 F7 H2 C4 PRO-REG | 50 | right | 5,000 m³/h | 3 A | see data sheet | CAIB/CAIT-10 to 50 PRO-REG | separate hot water and chilled water coils (H2 C4, H3 C4) | right | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B |
| CAIT-40 M5 F7 H3 C4 PRO-REG L | 5209380200 | CAIT M5 F7 H3 C4 PRO-REG | 40 | left | 4,000 m³/h | 2 A | 140 kg | CAIB/CAIT-10 to 50 PRO-REG | separate hot water and chilled water coils (H2 C4, H3 C4) | left | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B |
| CAIT-40 M5 F7 H3 C4 PRO-REG R | 5209380100 | CAIT M5 F7 H3 C4 PRO-REG | 40 | right | 4,000 m³/h | 2 A | 140 kg | CAIB/CAIT-10 to 50 PRO-REG | separate hot water and chilled water coils (H2 C4, H3 C4) | right | 3+N/400 V, 50 Hz | M5 (ePM10 ≥ 75%) and F7 (ePM1 ≥ 55%), double filtration, 48 mm each | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, EC motor, thermal contacts integrated in the electronics, insulation class B |
| CAIT-120 M5 H2 C3 PRO-REG ID L | 5209371800 | CAIT M5 H2 C3 PRO-REG ID | 120 | left | 12,000 m³/h | 9 A | 646 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-120 M5 H2 C3 PRO-REG ID R | 5209366400 | CAIT M5 H2 C3 PRO-REG ID | 120 | right | 12,000 m³/h | 9 A | 646 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-120 M5 H2 C3 PRO-REG ID L OI | 5209369100 | CAIT M5 H2 C3 PRO-REG ID OI | 120 | left | 12,000 m³/h | 9 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-120 M5 H2 C3 PRO-REG ID R OI | 5209363800 | CAIT M5 H2 C3 PRO-REG ID OI | 120 | right | 12,000 m³/h | 9 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-160 M5 H2 C4 PRO-REG ID L | 5209049800 | CAIT M5 H2 C4 PRO-REG ID | 160 | left | 16,000 m³/h | 8 A | 939 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-160 M5 H2 C4 PRO-REG ID R | 5209049300 | CAIT M5 H2 C4 PRO-REG ID | 160 | right | 16,000 m³/h | 8 A | 939 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-200 M5 H2 C4 PRO-REG ID L | 5209050200 | CAIT M5 H2 C4 PRO-REG ID | 200 | left | 20,000 m³/h | 16 A | 1118 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-200 M5 H2 C4 PRO-REG ID R | 5209049900 | CAIT M5 H2 C4 PRO-REG ID | 200 | right | 20,000 m³/h | 16 A | 1118 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H2 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-160 M5 H2 C4 PRO-REG ID L OI | 5209049600 | CAIT M5 H2 C4 PRO-REG ID OI | 160 | left | 16,000 m³/h | 8 A | 996 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-160 M5 H2 C4 PRO-REG ID R OI | 5209049400 | CAIT M5 H2 C4 PRO-REG ID OI | 160 | right | 16,000 m³/h | 8 A | 996 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-200 M5 H2 C4 PRO-REG ID L OI | 5209050100 | CAIT M5 H2 C4 PRO-REG ID OI | 200 | left | 20,000 m³/h | 16 A | 1184 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-200 M5 H2 C4 PRO-REG ID R OI | 5209050000 | CAIT M5 H2 C4 PRO-REG ID OI | 200 | right | 20,000 m³/h | 16 A | 1184 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-48 M5 H3 C4 PRO-REG L | 5209371600 | CAIT M5 H3 C4 PRO-REG | 48 | left | 5,000 m³/h | 2 A | 258 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H3 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-48 M5 H3 C4 PRO-REG R | 5209366200 | CAIT M5 H3 C4 PRO-REG | 48 | right | 5,000 m³/h | 2 A | 258 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H3 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-88 M5 H3 C4 PRO-REG L | 5209371700 | CAIT M5 H3 C4 PRO-REG | 88 | left | 9,000 m³/h | 4.5 A | 387 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H3 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-88 M5 H3 C4 PRO-REG R | 5209366300 | CAIT M5 H3 C4 PRO-REG | 88 | right | 9,000 m³/h | 4.5 A | 387 kg | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H3 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-48 M5 H3 C4 PRO-REG L OI | 5209368900 | CAIT M5 H3 C4 PRO-REG OI | 48 | left | 5,000 m³/h | 2 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-48 M5 H3 C4 PRO-REG R OI | 5209363600 | CAIT M5 H3 C4 PRO-REG OI | 48 | right | 5,000 m³/h | 2 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-88 M5 H3 C4 PRO-REG L OI | 5209369000 | CAIT M5 H3 C4 PRO-REG OI | 88 | left | 9,000 m³/h | 4.5 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | left | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
| CAIT-88 M5 H3 C4 PRO-REG R OI | 5209363700 | CAIT M5 H3 C4 PRO-REG OI | 88 | right | 9,000 m³/h | 4.5 A | n/a | CAIT-48 to 200 PRO-REG | separate hot water and chilled water coils (H2 C3, H3 C4) | right | 3/400 V, 50 Hz | M5 (ePM10 ≥ 75%) as standard; second slot for F7 (ePM1 ≥ 55%) as an accessory | plug fan with backward curved centrifugal impeller made of galvanised sheet steel, direct drive, three-phase EC motor, thermal contacts integrated in the electronics |
Features
Features
- Water coils mounted on a slide rail, accessible via the side panels.
- Scope of delivery according to the manufacturer: unit with control and ETD touch display (10 m cable).
Note on variants
Note on variants
The table above lists the S&P type and the item number for each option.