Free shipping from 100 € within Germany
English
Account WishlistCart
Blauberg Ventilatoren GmbH  |  SKU: 8051302

Blauberg Freshbox WiFi Decentralised Ventilation

2.98254 € 4.10949 €
Tax included Shipping calculated at checkout.
● Delivery time: 5 to 10 working days
● Shipping: Germany €4.99, free from €100; EU €19.99
✓ Original manufacturer unit, CE marked
✓ Quiet operation with the right sizing
✓ Pay by PayPal, card, Klarna or bank transfer
✓ Expert advice on choosing the right unit
Request a quote

For business customers, larger quantities or projects, we will be happy to prepare a quote for you.

  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
  • Bank transfer

You can also pay by bank transfer (prepayment). Bank details follow with the order confirmation.

Description

Blauberg Freshbox WiFi Decentralised Ventilation: Blauberg Freshbox WiFi decentralised ventilation units with heat recovery and Wi-Fi control. The suffix E stands for a built-in pre-heater, E1 for a post-heater and E2 for pre-heater and post-heater; ERV denotes the enthalpy heat exchanger. Selectable are heater, size and heat exchanger.

Technical data

Extract air filterG4
Temperature of the conveyed air-15 to 40 °C
Ambient temperature1 to 40 °C

Data per variant:

Heater (code)SizeHeat exchangerArticle numberPower supplyMaximum airflowMaximum current consumption without heaterSpeedSupply air filterConnection diameterHousingWeightDegree of protectionMaximum ambient humiditySound power levelSpecific energy consumption (SEC) class for average climateSpigot sizeMaximum current consumptionThermal efficiency of heat recoveryHousing materialInsulationWall thicknessPreheater power consumptionMaximum current consumption with heaterReheater power consumption
none100Enthalpy heat exchanger (ERV)80505101 phase, 110 to 240 V, 50/60 Hz100 m³/h0.4 Amax. 2200 min⁻¹G4 + F8 (optional F8 activated carbon or H13)100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%47 dB(A)A (scale A+ to G); SEC -38.3 kWh/(m²·a)n/an/an/an/an/an/an/an/an/a
none100Standard heat exchanger80448611 phase, 110 to 240 V, 50/60 Hz100 m³/h0.4 Amax. 2200 min⁻¹G4 + F8 (optional F8 activated carbon or H13)100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%47 dB(A)A (scale A+ to G); SEC -39.7 kWh/(m²·a)n/an/an/an/an/an/an/an/an/a
none200Enthalpy heat exchanger (ERV)80513021 phase, 230 V, 50/60 Hz200 m³/hn/a2000 min⁻¹G4 + F7 (H13 optional)n/an/a55 kgIP22, motor IP4460%36 dB(A)A (scale A+ to G); SEC -35.2 kWh/(m²·a)100 mm1.0 A68%polymer-coated steel30 mm70 to 2000 mmn/an/an/a
E100Enthalpy heat exchanger (ERV)80501211 phase, 230 V, 50/60 Hz100 m³/h0.4 Amax. 2200 min⁻¹G4 + F8 (optional F8 activated carbon or H13)100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%54 dB(A)A (scale A+ to G); SEC -40.4 kWh/(m²·a)n/an/an/an/an/an/a700 W3.6 An/a
E100Standard heat exchanger80505031 phase, 230 V, 50/60 Hz100 m³/h0.4 Amax. 2200 min⁻¹G4 + F8 (optional F8 activated carbon or H13)100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%47 dB(A)A (scale A+ to G); SEC -41.6 kWh/(m²·a)n/an/an/an/an/an/a700 W3.6 An/a
E200Enthalpy heat exchanger (ERV)80512961 phase, 230 V, 50/60 Hz200 m³/hn/a2000 min⁻¹G4 + F7 (optional H13)100 mmpolymer-coated steel, 30 mm insulation55 kgIP22 (motor IP44)60%36 dB(A)A (scale A+ to G); SEC -35.2 kWh/(m²·a)n/an/an/an/an/an/a650 W4.0 An/a
E1100Enthalpy heat exchanger (ERV)80509541 phase, 230 V100 m³/h0.4 Amax. 2200 min⁻¹G4100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%54 dB(A)A (scale A+ to G); SEC -40.4 kWh/(m²·a)n/an/an/an/an/an/an/a1.94 A350 W
E1100Standard heat exchanger80509471 phase, 230 V100 m³/h0.4 Amax. 2200 min⁻¹G4100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%54 dB(A)A (scale A+ to G); SEC -41.1 kWh/(m²·a)n/an/an/an/an/an/an/a1.94 A350 W
E1200Enthalpy heat exchanger (ERV)80517771 phase, 230 V, 50/60 Hz200 m³/hn/a2000 min⁻¹G4 + F7 (optional H13)100 mmpolymer-coated steel, 30 mm insulation55 kgIP22 (motor IP44)60%36 dB(A)A (scale A+ to G); SEC -35.2 kWh/(m²·a)n/an/an/an/an/an/an/a4.2 A700 W
E2100Enthalpy heat exchanger (ERV)80509781 phase, 230 V100 m³/h0.4 Amax. 2200 min⁻¹G4100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%54 dB(A)A (scale A+ to G); SEC -40.4 kWh/(m²·a)n/an/an/an/an/an/a700 W5.2 A350 W
E2100Standard heat exchanger80509611 phase, 230 V100 m³/h0.4 Amax. 2200 min⁻¹G4100 mmpolymer-coated steel, 10 mm insulation31 kgIP22 (motor IP44)70%47 dB(A)A (scale A+ to G); SEC -39.7 kWh/(m²·a)n/an/an/an/an/an/a700 W5.2 A350 W
E2200Enthalpy heat exchanger (ERV)80517841 phase, 230 V, 50/60 Hz200 m³/hn/a2000 min⁻¹G4 + F7 (H13 optional)n/an/a55 kgIP22, motor IP4460%36 dB(A)A (scale A+ to G); SEC -35.2 kWh/(m²·a)100 mmn/a68%polymer-coated steel30 mm70 to 2000 mm650 W7.2 A700 W

Applies to none / 100 / Standard heat exchanger, E / 100 / Standard heat exchanger, E1 / 100 / Standard heat exchanger and E2 / 100 / Standard heat exchanger:

Value according to the manufacturerSpeed 1Speed 2Speed 3Speed 4Speed 5
Power consumption without heater (W)2023293753
Airflow (m³/h)30446075100
Sound pressure level LpA at 3 m (dB(A))1320273339
Heat recovery efficiency according to EN 13141-8 (%)9895929089

Applies to none / 200 / Enthalpy heat exchanger (ERV) and E2 / 200 / Enthalpy heat exchanger (ERV):

Value according to the manufacturerSpeed 1Speed 2Speed 3Speed 4Speed 5
Airflow (m³/h)306090120200
Power consumption without heater (W)10152544134
Sound pressure level LpA at 3 m (dB(A))1222303645
Heat recovery efficiency according to EN 13141-8 (%)8581756866

Applies to E / 200 / Enthalpy heat exchanger (ERV) and E1 / 200 / Enthalpy heat exchanger (ERV):

Value according to the manufacturerSpeed 1Speed 2Speed 3Speed 4Speed 5
Power consumption without heater (W)10152544134
Airflow (m³/h)306090120200
Sound pressure level LpA at 3 m (dB(A))1222303645
Heat recovery efficiency according to EN 13141-8 (%)8581756866

Applies to none / 100 / Enthalpy heat exchanger (ERV), E / 100 / Enthalpy heat exchanger (ERV), E1 / 100 / Enthalpy heat exchanger (ERV) and E2 / 100 / Enthalpy heat exchanger (ERV):

Value according to the manufacturerSpeed 1Speed 2Speed 3Speed 4Speed 5
Power consumption without heater (W)2023293753
Airflow (m³/h)30446075100
Sound pressure level LpA at 3 m (dB(A))1320273339
Heat recovery efficiency according to EN 13141-8 (%)9694898583

Features

  • Control panel on the unit, remote control included and control by smartphone or tablet via Wi-Fi with the Blauberg Home app (Android and iOS).
  • Supply and extract air dampers with automatic actuators prevent draughts when the unit is switched off.
  • The supply and extract airflows remain completely separate during heat exchange.
  • EC external rotor motors with forward-curved impeller blades.

Note on variants

Select the heater (code), size and heat exchanger. The article number and technical data of each variant are listed in the table under Technical data; the price depends on the selected variant.

Data sheets and manuals (PDF)

Note on reviews: Any visitor can submit a review using the form; a purchase is not required. Anyone who submits a review receives an email to confirm their email address. Reviews marked “Verified” come from customers who bought the product from us. We do not check other reviews for a purchase.

Recommendations

From our range

Selected products from ventilation, filter and pipe technology.

View all recommendations →