{"title":"Duct and room sensors","description":"\u003cp\u003eDuct sensors and sensors record measured values such as carbon dioxide, relative humidity, temperature, air quality (VOC) or differential pressure and thus provide the basis for demand-controlled ventilation. In this category you will find sensors from S\u0026amp;P, Blauberg, Nilan, WANAS and Frico for installation in the air duct, wall mounting in the room or installation in the ventilation unit.\u003c\/p\u003e\n\u003ch2\u003eDuct sensors for supply and extract air\u003c\/h2\u003e\n\u003cp\u003eDuct sensors are inserted directly into the air duct. The \u003ca href=\"\/en\/products\/sp-sco2-k\"\u003eS\u0026amp;P SCO2\u003c\/a\u003e is available as duct sensor SCO2-K for carbon dioxide with an output signal of 0 to 10 V, the \u003ca href=\"\/en\/products\/sp-sft-a-n\"\u003eS\u0026amp;P SFT-K-N\u003c\/a\u003e measures temperature and relative humidity in the duct. For temperatures there is the \u003ca href=\"\/en\/products\/sp-tg-k\"\u003eS\u0026amp;P TG\u003c\/a\u003e series with duct sensors, contact sensors and room temperature sensors, including TG-K3\/PT1000. WANAS offers the duct sensor EXTRA TEMP PT-1000, which measures the temperature downstream of a heating or cooling coil. The S\u0026amp;P SL-101.1 monitors the air velocity in the duct (setting range 1 to 10 m\/s), the S\u0026amp;P KRM-X duct smoke detector detects smoke in the air stream.\u003c\/p\u003e\n\u003ch2\u003eRoom sensors for CO2, humidity and VOC\u003c\/h2\u003e\n\u003cp\u003eRoom sensors are mounted on the wall. The Blauberg sensors CD and \u003ca href=\"\/en\/products\/blauberg-dpwq40200\"\u003eDPWQ\/DPWC\u003c\/a\u003e measure carbon dioxide with an NDIR sensor in the range of 0 to 2000 ppm, VOC or temperature and humidity; according to the manufacturer the DPWQ\/DPWC sensors have analogue outputs 0 to 10 V and 4 to 20 mA. The \u003ca href=\"\/en\/products\/sp-scht-ad-0-10-v\"\u003eS\u0026amp;P SCHT-AD\u003c\/a\u003e records carbon dioxide, temperature and humidity and shows the values on a display. \u003ca href=\"\/en\/products\/sp-airsens-rh\"\u003eS\u0026amp;P AIRSENS\u003c\/a\u003e is available for CO2, humidity, temperature or VOC, with analogue output 0 to 10 V or 2 to 10 V, relay and Modbus RTU via RS-485. For simple switching tasks there are hygrostats such as S\u0026amp;P HIG-5 N and Blauberg HR-S as well as the S\u0026amp;P SQA air quality sensor with potential-free contact.\u003c\/p\u003e\n\u003ch2\u003eDifferential pressure for constant pressure and filter monitoring\u003c\/h2\u003e\n\u003cp\u003eAccording to S\u0026amp;P, differential pressure transmitters such as \u003ca href=\"\/en\/products\/sp-dpa2500-d-plus\"\u003eS\u0026amp;P DPA2500 PLUS\u003c\/a\u003e, the VCHV set and SPRD-010B are used for constant pressure operation (COP), VCHV and DPA2500 PLUS VV MultiRange also for constant air volume. The mechanical pressure switch S\u0026amp;P DS-400 with a measuring range of 30 to 400 Pa monitors air filter boxes, for example.\u003c\/p\u003e\n\u003ch2\u003eSensors for specific ventilation units\u003c\/h2\u003e\n\u003cp\u003eFor Nilan ventilation units there are \u003ca href=\"\/en\/products\/nilan-co2-sensorkit\"\u003esensor kits\u003c\/a\u003e with CO2 sensor, humidity sensor and pressure transmitter. The \u003ca href=\"\/en\/products\/wanas-co2-sensor-co2control-und-co2rcontrol-fuer-lueftungsgeraete\"\u003eWANAS CO2 sensors\u003c\/a\u003e CO2Control and CO2RControl adapt the ventilation level of WANAS units to demand, the CO2RControl version transmits wirelessly. Matching controllers can be found under \u003ca href=\"\/en\/collections\/zubehor-ersatzteile\"\u003eaccessories and spare parts\u003c\/a\u003e, background on carbon dioxide in the article \u003ca href=\"\/en\/blogs\/news\/co2-in-innenraumen-ab-wann-wird-die-luft-ungesund\"\u003eCO2 indoors\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions about duct sensors and sensors\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is a duct sensor?\u003c\/summary\u003e\u003cp\u003eA duct sensor is installed in a supply or extract air duct and measures, for example, carbon dioxide, temperature or relative humidity there. Examples in this category are S\u0026amp;P SCO2-K, SFT-K-N and TG-K as well as the WANAS duct sensor EXTRA TEMP PT-1000.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDo I also need a controller?\u003c\/summary\u003e\u003cp\u003eThat depends on the sensor. According to S\u0026amp;P, sensors with a 0 to 10 V output such as S\u0026amp;P SCO2, SFT or SCHT-AD require a control unit for fan control, for example CONTROL ECOWATT AC\/DC, or they are connected to the controls of the ventilation unit. S\u0026amp;P AIRSENS already has a built-in controller.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDo the sensors fit every ventilation unit?\u003c\/summary\u003e\u003cp\u003eNo. Manufacturer-specific sensors such as the Nilan sensor kits or the WANAS CO2 sensors are intended for that manufacturer's units. Please check the output signal and supply voltage in the product description or ask us.\u003c\/p\u003e\u003c\/details\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is a duct sensor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A duct sensor is installed in a supply or extract air duct and measures, for example, carbon dioxide, temperature or relative humidity there. Examples in this category are S\u0026P SCO2-K, SFT-K-N and TG-K as well as the WANAS duct sensor EXTRA TEMP PT-1000.\"}}, {\"@type\": \"Question\", \"name\": \"Do I also need a controller?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"That depends on the sensor. According to S\u0026P, sensors with a 0 to 10 V output such as S\u0026P SCO2, SFT or SCHT-AD require a control unit for fan control, for example CONTROL ECOWATT AC\/DC, or they are connected to the controls of the ventilation unit. S\u0026P AIRSENS already has a built-in controller.\"}}, {\"@type\": \"Question\", \"name\": \"Do the sensors fit every ventilation unit?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Manufacturer-specific sensors such as the Nilan sensor kits or the WANAS CO2 sensors are intended for that manufacturer's units. Please check the output signal and supply voltage in the product description or ask us.\"}}]}\u003c\/script\u003e","products":[{"product_id":"nilan-co2-sensorkit","title":"Nilan Sensors and Sensor Kits","description":"\u003cp\u003e\u003cstrong\u003eNilan Sensors and Sensor Kits\u003c\/strong\u003e combines the following versions in one product: CO2 sensor kit, CO2 control kit, humidity sensor, pressure transmitter. Select the required version under Type and then the matching variant under Version. The details for each version are given below.\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 sensor kit:\u003c\/strong\u003e \u003cstrong\u003eNilan CO2-Sensorkit\u003c\/strong\u003e is a retrofit kit with a carbon dioxide sensor for Nilan ventilation units with the CTS602 control. According to Nilan, ventilation is then controlled by the carbon dioxide content of the air: without increased load the unit runs at a low level; if the carbon dioxide content rises (for example due to more people in the room), the control increases ventilation. According to Nilan, the sensor is retrofitted in the ventilation unit. The Nilan wiring diagram for the kit (item numbers 7134B13 and 7134B14) shows the connection to the CTS602 board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 control kit:\u003c\/strong\u003e \u003cstrong\u003eNilan CO2 Control Kit\u003c\/strong\u003e (item number 7134B16). Manufacturer: Nilan (Nilan A\/S). According to Nilan, a carbon dioxide sensor controls ventilation on demand: when the carbon dioxide content of the air rises, the control increases ventilation. We have no manufacturer documents for item number 7134B16; we will clarify the scope of delivery and compatible units with you before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ehumidity sensor:\u003c\/strong\u003e \u003cstrong\u003eNilan Feuchtesensor\u003c\/strong\u003e is a humidity sensor for Nilan ventilation units. According to Nilan, with the sensor the unit automatically adapts the fan speed to the moisture content of the extract air and switches between low and high speed depending on humidity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003epressure transmitter:\u003c\/strong\u003e \u003cstrong\u003eNilan Drucktransmitter\u003c\/strong\u003e is a pressure transmitter for the pressure control of Nilan ventilation units with the CTS602 control. According to Nilan, the transmitters can be installed in the extract air or supply air duct. According to Nilan, the motor of the extract and\/or supply air fan can be controlled by one or two pressure transmitters.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCO2 sensor kit\u003c\/th\u003e\n\u003cth\u003eCO2 control kit\u003c\/th\u003e\n\u003cth\u003ehumidity sensor\u003c\/th\u003e\n\u003cth\u003epressure transmitter\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for\u003c\/td\u003e\n\u003ctd\u003eNilan ventilation units with CTS602 control\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003eNilan ventilation units with CTS602 control (pressure control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor according to wiring diagram\u003c\/td\u003e\n\u003ctd\u003eKCD-AN300 (carbon dioxide sensor, accessory)\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eanalogue input of the CTS602, sensor supply 24 V\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003efan speed adjustment according to the moisture content of the extract air\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation location\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003eextract air or supply air duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery (standard version according to Nilan)\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003epressure transmitter with 5 m cable, including power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect type and version. Not every combination is available.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2-Sensorkit\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e7134B14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2-Steuerungs-Kit\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e7134B16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeuchtesensor\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e239972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrucktransmitter\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e23994110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 sensor kit: Installed in the ventilation unit, retrofitting possible.\u003c\/li\u003e\n\u003cli\u003eCO2 sensor kit: According to the wiring diagram, a resistor R1 (150 kOhm) must be fitted with CTS602 software up to version 2.00x; from version 2.01x no resistor is required.\u003c\/li\u003e\n\u003cli\u003eCO2 sensor kit: The wiring diagram is available under downloads.\u003c\/li\u003e\n\u003cli\u003ehumidity sensor: A humidity sensor is listed as an accessory, for example, in the Nilan data sheet of the HCR 800T. Please check the documents of your unit to see whether it already has the sensor as standard.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nilan","offers":[{"title":"CO2 sensor kit \/ Standard","offer_id":51715972727125,"sku":"7134B14","price":656.99,"currency_code":"EUR","in_stock":true},{"title":"CO2 control kit \/ Standard","offer_id":55302804799829,"sku":"7134B16","price":725.99,"currency_code":"EUR","in_stock":true},{"title":"Humidity sensor \/ Standard","offer_id":55302804832597,"sku":"239972","price":364.49,"currency_code":"EUR","in_stock":true},{"title":"Pressure transmitter \/ Standard","offer_id":55302804865365,"sku":"23994110","price":2170.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/nilan-co2-sensorkit-7134B13-216_1f52e0ae-c01a-458e-93ac-00c661fc49bb.jpg?v=1761058636"},{"product_id":"blauberg-cd","title":"Blauberg CD","description":"\u003cp\u003e\u003cstrong\u003eBlauberg CD\u003c\/strong\u003e are Blauberg carbon dioxide sensors for demand-controlled ventilation. They measure the carbon dioxide concentration and control the output of fans or ventilation units according to the concentration. CD-1 and CD-2 are room sensors for surface wall mounting, CD-3 is a sensor board installed inside a ventilation unit in the extract air duct between extract air filter and heat exchanger.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eCarbon dioxide sensor with non-dispersive infrared sensor (NDIR), self-calibrating\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eCarbon dioxide measuring range\u003c\/th\u003e\u003ctd\u003e0 to 2000 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring accuracy\u003c\/th\u003e\u003ctd\u003e±30 ppm and ±3 % of the reading\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAmbient conditions\u003c\/th\u003e\u003ctd\u003e0 to +50 °C, 0 to 95 % relative humidity without condensation\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth\u003eOption in the shop\u003c\/th\u003e\u003cth\u003eModel\u003c\/th\u003e\u003cth\u003eVersion\u003c\/th\u003e\u003cth\u003ePower supply\u003c\/th\u003e\u003cth\u003eOutputs\u003c\/th\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eCD-1\u003c\/td\u003e\u003ctd\u003eCD-1\u003c\/td\u003e\u003ctd\u003eRoom sensor, surface wall mounting, 6 LEDs for indicating the carbon dioxide concentration, push button\u003c\/td\u003e\u003ctd\u003e24 V AC (50\/60 Hz) or 24 V DC, max. 1.6 W\u003c\/td\u003e\u003ctd\u003e0 to 10 V (switchable to 2 to 10 V, 0 to 20 mA, 4 to 20 mA) and potential-free relay contact (normally open, 2 A)\u003c\/td\u003e\u003ctd\u003e8014406\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eCD-2\u003c\/td\u003e\u003ctd\u003eCD-2\u003c\/td\u003e\u003ctd\u003eRoom sensor, surface wall mounting, without indicators and without on\/off button\u003c\/td\u003e\u003ctd\u003e24 V AC (50\/60 Hz) or 24 V DC, max. 1.6 W\u003c\/td\u003e\u003ctd\u003e0 to 10 V (switchable to 2 to 10 V, 0 to 20 mA, 4 to 20 mA) and potential-free relay contact (normally open, 2 A)\u003c\/td\u003e\u003ctd\u003e8014413\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eCD-3\u003c\/td\u003e\u003ctd\u003eCD-3\u003c\/td\u003e\u003ctd\u003eSensor board for installation in the extract air duct inside a ventilation unit\u003c\/td\u003e\u003ctd\u003e24 V AC\/DC (±10 %), below 1.5 W or 2.9 VA\u003c\/td\u003e\u003ctd\u003e0 to 10 V\u003c\/td\u003e\u003ctd\u003e8092305\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCD-1 and CD-2: relay output for switching the fan on and off according to carbon dioxide concentration, analogue output for continuous speed control; this requires a fan with EC motor or an additional speed controller with 0-10 V input\u003c\/li\u003e\n\u003cli\u003eCD-1: three operating modes via push button (always on, always off, operation according to carbon dioxide concentration); LEDs from green (below 600 ppm) through yellow to red (above 1600 ppm)\u003c\/li\u003e\n\u003cli\u003eCD-2: according to Blauberg for rooms where switching the ventilation on and off is not recommended, for example classrooms and public rooms\u003c\/li\u003e\n\u003cli\u003eCD-1 and CD-2: 24 V AC supply; socket for a power supply unit, available as accessory AT-220\/25; outer dimensions 100 × 80 × 30 mm\u003c\/li\u003e\n\u003cli\u003eCD-3: part of a ventilation system, not designed for stand-alone operation; service life of the sensor element according to the manufacturer 15 years; dimensions 76 × 40 × 15 mm; scope of delivery sensor, 4 nylon spacers and socket 15EDGK-3,5-03P-14 for connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eFor a room sensor with display and button choose CD-1, without controls CD-2. CD-3 is installed in a ventilation unit and connected via the plug to the control unit; the mounting position is given in the operating manual of the respective unit.\u003c\/p\u003e","brand":"Blauberg Ventilatoren GmbH","offers":[{"title":"CD-1","offer_id":53726516052309,"sku":"8014406","price":688.99,"currency_code":"EUR","in_stock":true},{"title":"CD-2","offer_id":53726516085077,"sku":"8014413","price":652.49,"currency_code":"EUR","in_stock":true},{"title":"CD-3","offer_id":53726516117845,"sku":"8092305","price":375.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/CD1.png?v=1759153219"},{"product_id":"blauberg-dpwq40200","title":"Blauberg Room Sensors DPWQ and DPWC for CO2, VOC, Temperature and Humidity","description":"\u003cp\u003e\u003cstrong\u003eBlauberg Room Sensors DPWQ and DPWC for CO2, VOC, Temperature and Humidity\u003c\/strong\u003e: room sensors from Blauberg for wall mounting for demand-controlled regulation of ventilation systems: DPWQ40200 for carbon dioxide, DPWQ30600 for VOC (air quality) and DPWC11200 for temperature and humidity. Options under measured variable: CO2 (DPWQ40200), VOC (DPWQ30600) and Temperature and humidity (DPWC11200).\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 (DPWQ40200):\u003c\/strong\u003e Blauberg DPWQ40200 is a sensor with self-calibration and microprocessor control for measuring the carbon dioxide content of the air in the range from 0 to 2000 ppm. The carbon dioxide content is measured with a non-dispersive infrared absorption analyser (NDIR). The analogue output allows continuous fan speed control in proportion to the carbon dioxide concentration; this requires a fan with EC motor or frequency drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVOC (DPWQ30600):\u003c\/strong\u003e Blauberg DPWQ30600 is a VOC sensor for measuring indoor air quality, with self-calibration and microprocessor control. According to the data sheet, it detects the degree of air saturation with pollutants such as cigarette smoke, exhaled air and solvent and cleaning agent vapours. The analogue output allows continuous fan speed control in proportion to air quality; this requires a fan with EC motor or frequency drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature and humidity (DPWC11200):\u003c\/strong\u003e Blauberg DPWC11200 is a temperature and humidity sensor for wall mounting in the room. According to the data sheet, it is used for temperature control and for controlling humidification and\/or dehumidification in ventilation, air conditioning and heating systems. The analogue output allows continuous fan speed control; this requires a fan with EC motor. The speed is controlled in proportion to humidity and temperature.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue outputs\u003c\/th\u003e\n\u003ctd\u003e0 to 10 V and 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCO2 (DPWQ40200)\u003c\/th\u003e\n\u003cth\u003eVOC (DPWQ30600)\u003c\/th\u003e\n\u003cth\u003eTemperature and humidity (DPWC11200)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCarbon dioxide sensor (NDIR), wall or junction box mounting\u003c\/td\u003e\n\u003ctd\u003eVOC sensor, room mounting\u003c\/td\u003e\n\u003ctd\u003eTemperature and humidity sensor, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e8 to 30 V DC \/ 12 to 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm\u003c\/td\u003e\n\u003ctd\u003e0 to 100 % air quality\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring accuracy\u003c\/td\u003e\n\u003ctd\u003e±30 ppm, ±5 % of maximum value\u003c\/td\u003e\n\u003ctd\u003e±20 %\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating conditions\u003c\/td\u003e\n\u003ctd\u003e0 to +50 °C, 10 to 90 % relative humidity without condensation\u003c\/td\u003e\n\u003ctd\u003e0 to +50 °C, 10 to 90 % relative humidity without condensation\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 °C, 10 to 90 % humidity without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter dimensions\u003c\/td\u003e\n\u003ctd\u003e95 × 97 × 30 mm\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003e127 × 80 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Measured variable.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 (DPWQ40200)\u003c\/td\u003e\n\u003ctd\u003e8066658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOC (DPWQ30600)\u003c\/td\u003e\n\u003ctd\u003e8066641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature and humidity (DPWC11200)\u003c\/td\u003e\n\u003ctd\u003e8068249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 (DPWQ40200): Mounting in the room on the wall or in a junction box\u003c\/li\u003e\n\u003cli\u003eCO2 (DPWQ40200): The data sheet (2018\/2019) contains wiring diagrams for KOMFORT Roto EC D\/S, CIVIC EC L and CIVIC EC D\u003c\/li\u003e\n\u003cli\u003eVOC (DPWQ30600): Sensitivity adjustable to the expected maximum level of air pollution\u003c\/li\u003e\n\u003cli\u003eVOC (DPWQ30600): Air exchange is automatically adapted to the specified level of air pollution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Blauberg Ventilatoren GmbH","offers":[{"title":"CO2 (DPWQ40200)","offer_id":53726530994517,"sku":"8066658","price":894.99,"currency_code":"EUR","in_stock":true},{"title":"VOC (DPWQ30600)","offer_id":55387621130581,"sku":"8066641","price":688.99,"currency_code":"EUR","in_stock":true},{"title":"Temperature and humidity (DPWC11200)","offer_id":55387621163349,"sku":"8068249","price":421.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/dpwq.png?v=1759153296"},{"product_id":"blauberg-hr-s","title":"Blauberg HR-S","description":"\u003cp\u003e\u003cstrong\u003eBlauberg HR-S\u003c\/strong\u003e is an electromechanical single-stage hygrostat for wall mounting indoors. According to the data sheet, it is designed for controlling humidification and\/or dehumidification in ventilation, air conditioning and heating systems and can also be used as an alarm device when the room humidity exceeds or falls below a preset value.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eElectromechanical hygrostat, single-stage\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eChangeover contact\u003c\/th\u003e\u003ctd\u003e250 V AC, 5 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eHumidity setting range\u003c\/th\u003e\u003ctd\u003e20 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eHousing material\u003c\/th\u003e\u003ctd\u003ePolycarbonate\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAmbient temperature\u003c\/th\u003e\u003ctd\u003e0 to +40 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP30\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOuter dimensions L × W × H\u003c\/th\u003e\u003ctd\u003e86 × 86 × 30 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003e8044748\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching via a sensing material that expands at high humidity and contracts at low humidity\u003c\/li\u003e\n\u003cli\u003eHumidification: normally open contact between terminals 1 and 2; dehumidification: normally open contact between terminals 1 and 3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Blauberg Ventilatoren GmbH","offers":[{"title":"Default Title","offer_id":53726552162645,"sku":"8044748","price":334.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/HRS.png?v=1759153304"},{"product_id":"sp-airsens-rh","title":"S\u0026P AIRSENS Air Quality Sensor with Controller","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P AIRSENS\u003c\/strong\u003e: Air Quality Sensor with Controller. Available are the versions AIRSENS CO2, AIRSENS RH, AIRSENS TEMP and AIRSENS VOC.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eS\u0026amp;P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e100 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue output\u003c\/th\u003e\n\u003ctd\u003e0 to 10 V or 2 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay\u003c\/th\u003e\n\u003ctd\u003e3 A, 250 V AC (NC and NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient humidity\u003c\/th\u003e\n\u003ctd\u003e10 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eModbus RTU, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class \/ degree of protection\u003c\/th\u003e\n\u003ctd\u003eII \/ IP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth\u003eS\u0026amp;P type\u003c\/th\u003e\u003cth\u003eItem number\u003c\/th\u003e\u003cth\u003eVersion\u003c\/th\u003e\u003cth\u003eMeasured variable\u003c\/th\u003e\u003cth\u003eTolerance\u003c\/th\u003e\u003cth\u003eWarm-up time\u003c\/th\u003e\u003cth\u003eMaximum power consumption\u003c\/th\u003e\u003cth\u003eHousing width x height\u003c\/th\u003e\u003cth\u003eWeight\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eAIRSENS CO2\u003c\/td\u003e\u003ctd\u003e5416845300\u003c\/td\u003e\u003ctd\u003eAIRSENS CO2\u003c\/td\u003e\u003ctd\u003ecarbon dioxide\u003c\/td\u003e\u003ctd\u003e± 30 ppm\u003c\/td\u003e\u003ctd\u003e1 minute\u003c\/td\u003e\u003ctd\u003e0.7 W\u003c\/td\u003e\u003ctd\u003e122 x 89 mm\u003c\/td\u003e\u003ctd\u003e150 g\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eAIRSENS RH\u003c\/td\u003e\u003ctd\u003e5416845500\u003c\/td\u003e\u003ctd\u003eAIRSENS RH\u003c\/td\u003e\u003ctd\u003erelative humidity (RH)\u003c\/td\u003e\u003ctd\u003e± 2%\u003c\/td\u003e\u003ctd\u003e30 seconds\u003c\/td\u003e\u003ctd\u003e0.7 W\u003c\/td\u003e\u003ctd\u003e122 x 89 mm\u003c\/td\u003e\u003ctd\u003e150 g\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eAIRSENS TEMP\u003c\/td\u003e\u003ctd\u003e5416071300\u003c\/td\u003e\u003ctd\u003eAIRSENS TEMP\u003c\/td\u003e\u003ctd\u003etemperature\u003c\/td\u003e\u003ctd\u003e± 0.4 °C\u003c\/td\u003e\u003ctd\u003en\/a\u003c\/td\u003e\u003ctd\u003e1 W\u003c\/td\u003e\u003ctd\u003en\/a\u003c\/td\u003e\u003ctd\u003en\/a\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eAIRSENS VOC\u003c\/td\u003e\u003ctd\u003e5416845400\u003c\/td\u003e\u003ctd\u003eAIRSENS VOC\u003c\/td\u003e\u003ctd\u003evolatile organic compounds (VOC)\u003c\/td\u003e\u003ctd\u003e± 100 ppm\u003c\/td\u003e\u003ctd\u003e1 minute\u003c\/td\u003e\u003ctd\u003e0.7 W\u003c\/td\u003e\u003ctd\u003e122 x 89 mm\u003c\/td\u003e\u003ctd\u003e150 g\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSet point adjustable via potentiometer; LED display in green, orange and red, brightness adjustable.\u003c\/li\u003e\n\u003cli\u003eNote according to S\u0026amp;P: with frequency inverters without an additional enable signal, a base load of 20 Hz or 40% of the maximum speed is permanently maintained.\u003c\/li\u003e\n\u003cli\u003eAs a wireless version, S\u0026amp;P offers the AIRSENS RF range with the REC.AIRSENS RF receiver.\u003c\/li\u003e\n\u003cli\u003eSelf-calibration: according to the instructions, adaptation to the installation site can take up to two weeks; the unit must remain switched on during this time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNote on variants\u003c\/h3\u003e\u003cp\u003eThe table above lists the S\u0026amp;P type and the item number for each option.\u003c\/p\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"AIRSENS CO2","offer_id":55302282314069,"sku":"5416845300","price":480.99,"currency_code":"EUR","in_stock":true},{"title":"AIRSENS RH","offer_id":53735648854357,"sku":"5416845500","price":326.49,"currency_code":"EUR","in_stock":true},{"title":"AIRSENS TEMP","offer_id":55302282346837,"sku":"5416071300","price":326.49,"currency_code":"EUR","in_stock":true},{"title":"AIRSENS VOC","offer_id":55281832395093,"sku":"5416845400","price":356.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-AIRSENS_89fcd26f-5f30-464c-9b90-94d9d9102653.jpg?v=1776780406"},{"product_id":"sp-airsens-rf-co2","title":"S\u0026P AIRSENS-RF Wireless Transmitter for CO2, Humidity or VOC","description":"\u003cp\u003e\u003cstrong\u003eS\u0026P AIRSENS-RF Wireless Transmitter for CO2, Humidity or VOC\u003c\/strong\u003e: wireless air quality sensor (radio transmitter) for demand-controlled ventilation, for carbon dioxide, relative humidity or VOC. The measured signal is sent by radio to the separately available receiver AIRSENS-RF-REC. Options under measured variable: CO2 (AIRSENS-RF-CO2), Relative humidity (AIRSENS-RF-RH) and VOC (AIRSENS-RF-VOC).\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 (AIRSENS-RF-CO2):\u003c\/strong\u003e S\u0026amp;P AIRSENS-RF-CO2 is a wireless air quality sensor (radio transmitter) for demand-controlled ventilation, version for the measured variable carbon dioxide. According to S\u0026amp;P, it transmits the measuring signal by radio to the REC.AIRSENS RF receiver (available separately), which is connected to the unit by cable. Up to four AIRSENS RF transmitters can be paired with one receiver to cover different areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelative humidity (AIRSENS-RF-RH):\u003c\/strong\u003e S\u0026amp;P AIRSENS-RF-RH is a wireless air quality sensor (radio transmitter) for demand-controlled ventilation, version for the measured variable relative humidity (RH). According to S\u0026amp;P, it transmits the measuring signal by radio to the REC.AIRSENS RF receiver (available separately), which is connected to the unit by cable. Up to four AIRSENS RF transmitters can be paired with one receiver to cover different areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVOC (AIRSENS-RF-VOC):\u003c\/strong\u003e S\u0026amp;P AIRSENS-RF-VOC is a wireless air quality sensor (radio transmitter) for demand-controlled ventilation, version for the measured variable volatile organic compounds (VOC). According to S\u0026amp;P, it transmits the measuring signal by radio to the REC.AIRSENS RF receiver (available separately), which is connected to the unit by cable. Up to four AIRSENS RF transmitters can be paired with one receiver to cover different areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e100 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue output\u003c\/th\u003e\n\u003ctd\u003e0 to 10 V or 2 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay\u003c\/th\u003e\n\u003ctd\u003e3 A, 250 V AC (NC and NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRadio frequency\u003c\/th\u003e\n\u003ctd\u003e868.3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eModbus RTU, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class \/ degree of protection\u003c\/th\u003e\n\u003ctd\u003eII \/ IP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient humidity\u003c\/th\u003e\n\u003ctd\u003e10 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing width x height\u003c\/th\u003e\n\u003ctd\u003e122 x 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCO2 (AIRSENS-RF-CO2)\u003c\/th\u003e\n\u003cth\u003eRelative humidity (AIRSENS-RF-RH)\u003c\/th\u003e\n\u003cth\u003eVOC (AIRSENS-RF-VOC)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured variable\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide\u003c\/td\u003e\n\u003ctd\u003erelative humidity (RH)\u003c\/td\u003e\n\u003ctd\u003evolatile organic compounds (VOC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e450 to 2,000 ppm\u003c\/td\u003e\n\u003ctd\u003e45 to 100%\u003c\/td\u003e\n\u003ctd\u003e450 to 2,000 ppm (as carbon dioxide equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTolerance\u003c\/td\u003e\n\u003ctd\u003e± 30 ppm\u003c\/td\u003e\n\u003ctd\u003e± 2%\u003c\/td\u003e\n\u003ctd\u003e± 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-up time\u003c\/td\u003e\n\u003ctd\u003e1 minute\u003c\/td\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003ctd\u003e1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Measured variable.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 (AIRSENS-RF-CO2)\u003c\/td\u003e\n\u003ctd\u003e5416025200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity (AIRSENS-RF-RH)\u003c\/td\u003e\n\u003ctd\u003e5416025400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOC (AIRSENS-RF-VOC)\u003c\/td\u003e\n\u003ctd\u003e5416025300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour operating modes, set via DIP switches: relay + Modbus (read), 0 to 10 V analogue output + Modbus (read), 2 to 10 V analogue output + Modbus (read) and Modbus control.\u003c\/li\u003e\n\u003cli\u003eSet point adjustable via potentiometer; LED display in green, orange and red, brightness adjustable.\u003c\/li\u003e\n\u003cli\u003eCO2 (AIRSENS-RF-CO2): Self-calibration: according to the instructions, adaptation to the installation site can take up to two weeks; the unit must remain switched on during this time. Manual calibration is also possible.\u003c\/li\u003e\n\u003cli\u003ePairing with the receiver via a button on the transmitter; the connection can be tested via the same button.\u003c\/li\u003e\n\u003cli\u003eThe REC.AIRSENS RF receiver is not included in the scope of delivery.\u003c\/li\u003e\n\u003cli\u003eVOC (AIRSENS-RF-VOC): Self-calibration: according to the instructions, adaptation to the installation site can take up to two weeks; the unit must remain switched on during this time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes on installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation by a qualified specialist; mount in a dry location on a flat surface, fixed at four points.\u003c\/li\u003e\n\u003cli\u003eRecommended mounting height according to the instructions 1.5 to 1.8 m, not in direct sunlight, in air currents from windows, doors or ventilation systems or directly at permanently occupied places.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"CO2 (AIRSENS-RF-CO2)","offer_id":53735649018197,"sku":"5416025200","price":512.99,"currency_code":"EUR","in_stock":true},{"title":"Relative humidity (AIRSENS-RF-RH)","offer_id":55387168080213,"sku":"5416025400","price":252.49,"currency_code":"EUR","in_stock":true},{"title":"VOC (AIRSENS-RF-VOC)","offer_id":55387168112981,"sku":"5416025300","price":392.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-AIRSENS_8eadfffb-ee4e-477c-864e-2e61ae546edf.jpg?v=1776780412"},{"product_id":"sp-dpa2500-d-plus","title":"S\u0026P DPA2500 PLUS Differential Pressure Transmitter","description":"\u003cp\u003e\u003cstrong\u003eS\u0026P DPA2500 PLUS Differential Pressure Transmitter\u003c\/strong\u003e: transmitter for differential pressure, as DPA2500-D PLUS with display or as DPA2500 PLUS VV MultiRange additionally for volume flow. Options under type: DPA2500-D PLUS, differential pressure, with display and DPA2500 PLUS VV MultiRange, differential pressure and volume flow.\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDPA2500-D PLUS, differential pressure, with display:\u003c\/strong\u003e S\u0026amp;P DPA2500-D PLUS is a differential pressure transmitter with output signal 0 to 10 V or 4 to 20 mA, without set point specification, with display. According to S\u0026amp;P, it is used for constant pressure operation (COP) in conjunction with a control unit, for example CONTROL ECOWATT AC\/DC, or with the controller of a ventilation unit. In the data sheet of the CAD-COMPACT ADVANCED ventilation units, S\u0026amp;P lists it for COP constant pressure control, supplied via the APG-160-Trafo-230V-24V transformer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDPA2500 PLUS VV MultiRange, differential pressure and volume flow:\u003c\/strong\u003e S\u0026amp;P DPA2500 PLUS VV MultiRange is a differential pressure transmitter with output signal 0 to 10 V or 4 to 20 mA, without set point specification. According to S\u0026amp;P, it is used for constant pressure operation (COP) in conjunction with a control unit, for example CONTROL ECOWATT AC\/DC, or with the controller of a ventilation unit. In the data sheet of the CAD-COMPACT ADVANCED ventilation units, S\u0026amp;P lists it for COP constant pressure control, supplied via the APG-160-Trafo-230V-24V transformer.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\/DC (± 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput signal\u003c\/th\u003e\n\u003ctd\u003e0 to 10 V \/ 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure measuring range\u003c\/th\u003e\n\u003ctd\u003e0 to 2,500 Pa, 8 adjustable measuring ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e75 x 80 x 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Type.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPA2500-D PLUS, differential pressure, with display\u003c\/td\u003e\n\u003ctd\u003e0121222001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPA2500 PLUS VV MultiRange, differential pressure and volume flow\u003c\/td\u003e\n\u003ctd\u003e8007090030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor gaseous, non-aggressive media.\u003c\/li\u003e\n\u003cli\u003eHousing made of impact-resistant plastic.\u003c\/li\u003e\n\u003cli\u003eIncluding measuring nozzle set (according to the manufacturer).\u003c\/li\u003e\n\u003cli\u003eDPA2500-D PLUS, differential pressure, with display: With display; the version without display is the DPA2500 PLUS VV MultiRange.\u003c\/li\u003e\n\u003cli\u003eA transformer is required for the 24 V power supply, for example APG-160-Trafo-230V-24V.\u003c\/li\u003e\n\u003cli\u003eDPA2500 PLUS VV MultiRange, differential pressure and volume flow: The version with display is the DPA2500-D PLUS.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"DPA2500-D PLUS, differential pressure, with display","offer_id":53735847067989,"sku":"0121222001","price":429.99,"currency_code":"EUR","in_stock":true},{"title":"DPA2500 PLUS VV MultiRange, differential pressure and volume flow","offer_id":55387219493205,"sku":"8007090030","price":260.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-121222001.jpg?v=1776786022"},{"product_id":"sp-ds-400","title":"S\u0026P DS-400 Differential Pressure Switch","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P DS-400\u003c\/strong\u003e is a mechanical pressure switch for non-aggressive gases for monitoring air filter boxes, fans and system negative pressure.\u003c\/p\u003e\u003cp\u003eAccording to S\u0026amp;P, the switching pressure is set on an adjusting wheel with a reference scale.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003eL012115901\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e30 to 400 Pa\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSwitching differential\u003c\/th\u003e\u003ctd\u003e15 Pa\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMax. switching capacity\u003c\/th\u003e\u003ctd\u003e1.5 A (0.4 A) \/ 250 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMedium temperature\u003c\/th\u003e\u003ctd\u003e-30 to +80 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP54\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003eapprox. 85 x 102 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eMechanical pressure switch with adjusting wheel and reference scale.\u003c\/li\u003e\u003cli\u003eConnection set included in the scope of delivery (according to the manufacturer).\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53735848018261,"sku":"L012115901","price":51.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-DS_1543d61b-3e63-462e-9bf8-905d86e3a9f6.jpg?v=1776780455"},{"product_id":"sp-hig-5-n","title":"S\u0026P HIG-5 N Humidistat","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P HIG-5 N\u003c\/strong\u003e is a hygrostat from S\u0026amp;P for the humidity dependent control of one or more fans, for surface mounting. It switches via a potential-free changeover contact.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003e8007090031\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eVoltage\u003c\/th\u003e\u003ctd\u003e1~ 230 V, 50 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eWorking range\u003c\/th\u003e\u003ctd\u003e35 to 95% relative humidity\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSwitching differential\u003c\/th\u003e\u003ctd\u003eapprox. 3% relative humidity\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMax. switching capacity\u003c\/th\u003e\u003ctd\u003e3 A, 5 A in dehumidification mode\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAmbient temperature\u003c\/th\u003e\u003ctd\u003e10 to 60 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eProtection class\u003c\/th\u003e\u003ctd\u003eII\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP 30\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e84.5 x 84.5 x 25 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePotential-free changeover contact (dehumidifying or humidifying)\u003c\/li\u003e\u003cli\u003eSurface mounting\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53736002453845,"sku":"8007090031","price":156.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-HIG-5-H_021332be-f86e-4341-ab63-027bce60f066.jpg?v=1776778859"},{"product_id":"sp-krm-x-1-016-230-v","title":"S\u0026P KRM-X Duct Smoke Detector","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P KRM-X\u003c\/strong\u003e: Duct Smoke Detector. Available are the versions KRM-X 24V, KRM-X 230V, KRM-X BAC and KRM-X MOD as well as the sizes 2 0,16 and 1 0,16.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eS\u0026amp;P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible humidity\u003c\/th\u003e\n\u003ctd\u003e10 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. switching capacity alarm relay\u003c\/th\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible air velocity\u003c\/th\u003e\n\u003ctd\u003e1 to 20 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth\u003eS\u0026amp;P type\u003c\/th\u003e\u003cth\u003eItem number\u003c\/th\u003e\u003cth\u003eVersion\u003c\/th\u003e\u003cth\u003eSize\u003c\/th\u003e\u003cth\u003eSupply voltage\u003c\/th\u003e\u003cth\u003eRated current\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eKRM-X-2-0,16-24 V\u003c\/td\u003e\u003ctd\u003eL012113209\u003c\/td\u003e\u003ctd\u003eKRM-X 24V\u003c\/td\u003e\u003ctd\u003e2 0,16\u003c\/td\u003e\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\u003ctd\u003e120 mA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eKRM-X-1-0,16-230 V\u003c\/td\u003e\u003ctd\u003eL012113208\u003c\/td\u003e\u003ctd\u003eKRM-X 230V\u003c\/td\u003e\u003ctd\u003e1 0,16\u003c\/td\u003e\u003ctd\u003e230 V AC\u003c\/td\u003e\u003ctd\u003e30 mA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eKRM-X-2-0,16-BAC\u003c\/td\u003e\u003ctd\u003eL012113210\u003c\/td\u003e\u003ctd\u003eKRM-X BAC\u003c\/td\u003e\u003ctd\u003e2 0,16\u003c\/td\u003e\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\u003ctd\u003e120 mA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eKRM-X-2-0,16-MOD\u003c\/td\u003e\u003ctd\u003eL012113211\u003c\/td\u003e\u003ctd\u003eKRM-X MOD\u003c\/td\u003e\u003ctd\u003e2 0,16\u003c\/td\u003e\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\u003ctd\u003e120 mA\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUniversal length 0.16 m for monitoring all duct cross-sections from Ø 100 mm\u003c\/li\u003e\n\u003cli\u003eVdS approval according to the manufacturer (G219046\/G219053)\u003c\/li\u003e\n\u003cli\u003ePatented single-tube air measuring system according to the manufacturer\u003c\/li\u003e\n\u003cli\u003eContamination display in % and message at 70%\u003c\/li\u003e\n\u003cli\u003eElectronic air flow monitoring\u003c\/li\u003e\n\u003cli\u003eReset button in the housing operable from outside, remote reset via terminals possible\u003c\/li\u003e\n\u003cli\u003eAs optional accessories, S\u0026amp;P lists the splash-proof housing KRM-WDG-X-N for outdoor installation or in cold environments, the KRM-KS bracket for mounting on round or insulated ducts and the KRM-KS-WDG-X bracket when using the KRM-WDG-X-N housing.\u003c\/li\u003e\n\u003cli\u003eRS485 bus interface (according to S\u0026amp;P only on the -MOD and -BAC versions)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNote on variants\u003c\/h3\u003e\u003cp\u003eThe table above lists the S\u0026amp;P type and the item number for each option.\u003c\/p\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"KRM-X 24V \/ 2 0.16","offer_id":55282038997333,"sku":"L012113209","price":853.99,"currency_code":"EUR","in_stock":true},{"title":"KRM-X 230V \/ 1 0.16","offer_id":53736071758165,"sku":"L012113208","price":872.49,"currency_code":"EUR","in_stock":true},{"title":"KRM-X BAC \/ 2 0.16","offer_id":55302654787925,"sku":"L012113210","price":909.49,"currency_code":"EUR","in_stock":true},{"title":"KRM-X MOD \/ 2 0.16","offer_id":55302654820693,"sku":"L012113211","price":909.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-KRM-X_d646ac6c-eb81-4be6-8c5b-798435b34525.jpg?v=1776780506"},{"product_id":"sp-scht-ad-0-10-v","title":"S\u0026P SCHT-AD 0-10 V","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P SCHT-AD 0-10 V\u003c\/strong\u003e is a room sensor with display from S\u0026amp;P for measuring carbon dioxide, temperature and relative humidity with an analogue 0 to 10 V output signal, for wall mounting in the room.\u003c\/p\u003e\u003cp\u003eAccording to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003e5416731100\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasured variables\u003c\/th\u003e\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm, temperature 0 to 50 °C, relative humidity 0 to 100%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisplay\u003c\/th\u003e\u003ctd\u003eyes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSupply voltage\u003c\/th\u003e\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOutput signal\u003c\/th\u003e\u003ctd\u003e0 to 10 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eInstallation\u003c\/th\u003e\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRecommended mounting height\u003c\/th\u003e\u003ctd\u003e1.5 to 3.5 m\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP 20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e85 x 100 x 26 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eCarbon dioxide measurement every 30 seconds according to the instructions, with self-calibration (long-term stability according to the manufacturer 20 ppm per year)\u003c\/li\u003e\u003cli\u003eOperating environment according to the instructions -5 to +55 °C, max. 90% relative humidity without condensation\u003c\/li\u003e\u003cli\u003eAccording to the instructions, do not install in direct sunlight or outdoors, and keep at least 1 m away from workstations\u003c\/li\u003e\u003cli\u003eS\u0026amp;P lists the SCHT-AD as room sensor with display among others for the CAD-COMPACT ADVANCED, CADB\/T-HE PRO-REG and RHE ventilation units.\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53736168587605,"sku":"5416731100","price":1287.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-5416731100.jpg?v=1776793054"},{"product_id":"sp-sft-a-n","title":"S\u0026P SFT Humidity and Temperature Sensors for Room and Duct","description":"\u003cp\u003e\u003cstrong\u003eS\u0026P SFT Humidity and Temperature Sensors for Room and Duct\u003c\/strong\u003e: sensors from S\u0026P for measuring temperature and relative humidity with analogue output signal 0 to 10 V, as room sensors for surface mounting or as duct sensors. Options under type: SFT-A-N, room sensor humidity and temperature, SFT-A, room sensor humidity and temperature and SFT-K-N, duct sensor humidity and temperature.\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSFT-A-N, room sensor humidity and temperature:\u003c\/strong\u003e S\u0026amp;P SFT-A-N is a room sensor from S\u0026amp;P for measuring temperature and relative humidity with an analogue 0 to 10 V output signal, for surface mounting. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSFT-A, room sensor humidity and temperature:\u003c\/strong\u003e S\u0026amp;P SFT-A is a room sensor from S\u0026amp;P for measuring temperature and relative humidity with an analogue 0 to 10 V output signal, for surface mounting. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSFT-K-N, duct sensor humidity and temperature:\u003c\/strong\u003e S\u0026amp;P SFT-K-N is a duct sensor from S\u0026amp;P for measuring temperature and relative humidity in ventilation ducts, with an analogue 0 to 10 V output signal. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput signal\u003c\/th\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSFT-A-N, room sensor humidity and temperature\u003c\/th\u003e\n\u003cth\u003eSFT-A, room sensor humidity and temperature\u003c\/th\u003e\n\u003cth\u003eSFT-K-N, duct sensor humidity and temperature\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured variables\u003c\/td\u003e\n\u003ctd\u003etemperature 0 to 50 °C, relative humidity 0 to 100%\u003c\/td\u003e\n\u003ctd\u003etemperature 0 to 50 °C, relative humidity 0 to 100%\u003c\/td\u003e\n\u003ctd\u003etemperature -20 to +80 °C, relative humidity 0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e3 to 5 W\u003c\/td\u003e\n\u003ctd\u003e3 to 5 W\u003c\/td\u003e\n\u003ctd\u003e0.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\n\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended mounting height\u003c\/td\u003e\n\u003ctd\u003e1.5 to 3.5 m\u003c\/td\u003e\n\u003ctd\u003e1.5 to 3.5 m\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP 30\u003c\/td\u003e\n\u003ctd\u003eIP 30\u003c\/td\u003e\n\u003ctd\u003eIP 30 (sensor) \/ IP 65 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e85 x 85 x 25 mm\u003c\/td\u003e\n\u003ctd\u003e85 x 85 x 25 mm\u003c\/td\u003e\n\u003ctd\u003ehousing 68 x 63 x 40 mm, probe Ø 19.5 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Type.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFT-A-N, room sensor humidity and temperature\u003c\/td\u003e\n\u003ctd\u003eL012122202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFT-A, room sensor humidity and temperature\u003c\/td\u003e\n\u003ctd\u003e8007090017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFT-K-N, duct sensor humidity and temperature\u003c\/td\u003e\n\u003ctd\u003e8007090032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSFT-A-N, room sensor humidity and temperature: No display\u003c\/li\u003e\n\u003cli\u003eSFT-A, room sensor humidity and temperature: No display\u003c\/li\u003e\n\u003cli\u003eSFT-A, room sensor humidity and temperature: S\u0026amp;P lists the SFT-A as room sensor for humidity and temperature among others for the CAD-COMPACT ADVANCED and CADB\/T-HE PRO-REG ventilation units.\u003c\/li\u003e\n\u003cli\u003eSFT-K-N, duct sensor humidity and temperature: S\u0026amp;P lists the SFT-K-N as duct sensor for humidity and temperature among others for the CAD-COMPACT ADVANCED, CADB\/T-HE PRO-REG and RHE ventilation units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"SFT-A-N, room sensor humidity and temperature","offer_id":53736172749141,"sku":"L012122202","price":363.49,"currency_code":"EUR","in_stock":true},{"title":"SFT-A, room sensor humidity and temperature","offer_id":55387311374677,"sku":"8007090017","price":363.49,"currency_code":"EUR","in_stock":true},{"title":"SFT-K-N, duct sensor humidity and temperature","offer_id":55387311407445,"sku":"8007090032","price":386.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-SFT-A_e8d7e760-5490-4fc8-b518-9ae67f2b6f69.jpg?v=1776780538"},{"product_id":"sp-sco2-k","title":"S\u0026P SCO2 CO2 Sensors for Room and Duct","description":"\u003cp\u003e\u003cstrong\u003eS\u0026P SCO2 CO2 Sensors for Room and Duct\u003c\/strong\u003e: carbon dioxide sensors from S\u0026P for demand-controlled ventilation, as room sensors for surface mounting or as duct sensors, some additionally with temperature and humidity measurement. 6 versions are available under type.\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2-K, duct sensor CO2, 0 to 10 V:\u003c\/strong\u003e S\u0026amp;P SCO2-K is a duct sensor from S\u0026amp;P for measuring carbon dioxide in ventilation ducts, with an analogue 0 to 10 V output signal. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2-AC-N, room sensor CO2, 0 to 10 V:\u003c\/strong\u003e S\u0026amp;P SCO2-AC-N is a room sensor from S\u0026amp;P for measuring carbon dioxide with an analogue 0 to 10 V output signal, for surface mounting. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2-AR, room sensor CO2, switching:\u003c\/strong\u003e S\u0026amp;P SCO2-AR is a room sensor from S\u0026amp;P for the carbon dioxide dependent control of one or more fans with hysteresis function. It switches via a potential-free contact; set point and switching differential are adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2FT-K-N, duct sensor CO2, humidity and temperature:\u003c\/strong\u003e S\u0026amp;P SCO2FT-K-N is a duct sensor from S\u0026amp;P for measuring carbon dioxide, temperature and relative humidity in ventilation ducts, with an analogue 0 to 10 V output signal. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2T-A, room sensor CO2 and temperature:\u003c\/strong\u003e S\u0026amp;P SCO2T-A is a room sensor from S\u0026amp;P for measuring carbon dioxide and temperature with an analogue 0 to 10 V output signal, for surface mounting. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSCO2T-AD, room sensor CO2 and temperature, with display:\u003c\/strong\u003e S\u0026amp;P SCO2T-AD is a room sensor with display from S\u0026amp;P for measuring carbon dioxide and temperature with an analogue 0 to 10 V output signal, for surface mounting. According to S\u0026amp;P, the measured value is converted into a proportional signal of 0 to 10 V (for example 45% relative humidity = 4.5 V). For fan control, an additional control unit is required, for example CONTROL ECOWATT AC\/DC; the sensors can also be connected to the control system of ventilation units. In both cases, the set point is set on the controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSCO2-K, duct sensor CO2, 0 to 10 V\u003c\/th\u003e\n\u003cth\u003eSCO2-AC-N, room sensor CO2, 0 to 10 V\u003c\/th\u003e\n\u003cth\u003eSCO2-AR, room sensor CO2, switching\u003c\/th\u003e\n\u003cth\u003eSCO2FT-K-N, duct sensor CO2, humidity and temperature\u003c\/th\u003e\n\u003cth\u003eSCO2T-A, room sensor CO2 and temperature\u003c\/th\u003e\n\u003cth\u003eSCO2T-AD, room sensor CO2 and temperature, with display\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured variables\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm, temperature -20 to +80 °C, relative humidity 0 to 100%\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm, temperature 0 to 50 °C\u003c\/td\u003e\n\u003ctd\u003ecarbon dioxide 0 to 2,000 ppm, temperature 0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003ctd\u003e15 to 35 V DC or 24 V AC (transformer required for power supply)\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput signal\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\n\u003ctd\u003eSurface mounting\u003c\/td\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\n\u003ctd\u003eSurface mounting (room sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP 30 (sensor) \/ IP 65 (housing)\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003ctd\u003eIP 30 (sensor) \/ IP 65 (housing)\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e2.3 W\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003e3 to 5 W\u003c\/td\u003e\n\u003ctd\u003e3 to 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ehousing 90 x 88 x 52 mm\u003c\/td\u003e\n\u003ctd\u003e85 x 85 x 25 mm\u003c\/td\u003e\n\u003ctd\u003e85 x 100 x 26 mm\u003c\/td\u003e\n\u003ctd\u003ehousing 84 x 84 x 44 mm, probe Ø 19.5 x 180 mm\u003c\/td\u003e\n\u003ctd\u003e85 x 100 x 26 mm\u003c\/td\u003e\n\u003ctd\u003e85 x 100 x 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Type.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2-K, duct sensor CO2, 0 to 10 V\u003c\/td\u003e\n\u003ctd\u003eL012122203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2-AC-N, room sensor CO2, 0 to 10 V\u003c\/td\u003e\n\u003ctd\u003eL012122201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2-AR, room sensor CO2, switching\u003c\/td\u003e\n\u003ctd\u003e5416803800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2FT-K-N, duct sensor CO2, humidity and temperature\u003c\/td\u003e\n\u003ctd\u003e8007090033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2T-A, room sensor CO2 and temperature\u003c\/td\u003e\n\u003ctd\u003e5401221000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCO2T-AD, room sensor CO2 and temperature, with display\u003c\/td\u003e\n\u003ctd\u003e5416730900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCO2-K, duct sensor CO2, 0 to 10 V: Duct sensor for demand-controlled ventilation according to carbon dioxide concentration in combination with a control unit\u003c\/li\u003e\n\u003cli\u003eSCO2-AC-N, room sensor CO2, 0 to 10 V: Room sensor for demand-controlled ventilation according to carbon dioxide concentration in combination with a control unit\u003c\/li\u003e\n\u003cli\u003eSCO2-AR, room sensor CO2, switching: Potential-free contact (ventilation ON\/OFF)\u003c\/li\u003e\n\u003cli\u003eSCO2-AR, room sensor CO2, switching: Set point and switching differential adjustable\u003c\/li\u003e\n\u003cli\u003eSCO2-AR, room sensor CO2, switching: According to S\u0026amp;P, a transformer is required for the power supply.\u003c\/li\u003e\n\u003cli\u003eSCO2FT-K-N, duct sensor CO2, humidity and temperature: S\u0026amp;P lists this sensor as a duct sensor among others for the CAD-COMPACT ADVANCED and CADB\/T-HE PRO-REG ventilation units.\u003c\/li\u003e\n\u003cli\u003eSCO2T-A, room sensor CO2 and temperature: No display\u003c\/li\u003e\n\u003cli\u003eSCO2T-A, room sensor CO2 and temperature: According to S\u0026amp;P, humidity can also be measured with the S-RF retrofit module (article number 8070304103).\u003c\/li\u003e\n\u003cli\u003eSCO2T-A, room sensor CO2 and temperature: S\u0026amp;P lists this room sensor among others for the CAD-COMPACT ADVANCED and CADB\/T-HE PRO-REG ventilation units.\u003c\/li\u003e\n\u003cli\u003eSCO2T-AD, room sensor CO2 and temperature, with display: Display for showing the measured values\u003c\/li\u003e\n\u003cli\u003eSCO2T-AD, room sensor CO2 and temperature, with display: According to S\u0026amp;P, humidity can also be measured with the S-RF retrofit module (article number 8070304103).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"SCO2-K, duct sensor CO2, 0 to 10 V","offer_id":53736173109589,"sku":"L012122203","price":510.49,"currency_code":"EUR","in_stock":true},{"title":"SCO2-AC-N, room sensor CO2, 0 to 10 V","offer_id":55387301839189,"sku":"L012122201","price":472.99,"currency_code":"EUR","in_stock":true},{"title":"SCO2-AR, room sensor CO2, switching","offer_id":55387301871957,"sku":"5416803800","price":591.49,"currency_code":"EUR","in_stock":true},{"title":"SCO2FT-K-N, duct sensor CO2, humidity and temperature","offer_id":55387301904725,"sku":"8007090033","price":806.49,"currency_code":"EUR","in_stock":true},{"title":"SCO2T-A, room sensor CO2 and temperature","offer_id":55387301937493,"sku":"5401221000","price":963.49,"currency_code":"EUR","in_stock":true},{"title":"SCO2T-AD, room sensor CO2 and temperature, with display","offer_id":55387301970261,"sku":"5416730900","price":973.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-L012122203.jpg?v=1776793064"},{"product_id":"sp-sl-1011-230","title":"S\u0026P SL-101.1 230 Airflow Monitor, Duct Installation, 230V","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P SL-101.1 230\u003c\/strong\u003e is a duct sensor from S\u0026amp;P for monitoring the air velocity in gaseous media of ventilation systems, for example in supply and exhaust air ducts. When the set air velocity is reached, it switches a contact.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003eL012113205\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSupply voltage\u003c\/th\u003e\u003ctd\u003e230 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMax. switching capacity\u003c\/th\u003e\u003ctd\u003e3 A (at 230 V)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSetting range\u003c\/th\u003e\u003ctd\u003e1 to 10 m\/s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP 65\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e142 x Ø 23 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFor gaseous, non-aggressive media\u003c\/li\u003e\u003cli\u003eHousing made of impact-resistant plastic\u003c\/li\u003e\u003cli\u003ePUR cable 2 m, 4 x 0.5 mm²\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53736216297813,"sku":"L012113205","price":287.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-SL-230_3c1c5430-20c9-4717-9df2-229534a19028.jpg?v=1776780595"},{"product_id":"sp-sqa","title":"S\u0026P SQA Air Quality Sensor","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P SQA\u003c\/strong\u003e is an air quality sensor from S\u0026amp;P for the room air dependent control of one or more fans, for surface mounting. According to S\u0026amp;P, the device reacts among other things to carbon monoxide, benzene, alcohol, methane and tobacco smoke.\u003c\/p\u003e\u003cp\u003eAccording to S\u0026amp;P, the sensor can be used neither as a fire gas detector nor as a fire alarm device.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003e5401220800\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eVoltage\u003c\/th\u003e\u003ctd\u003e1~ 230 V, 50 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMax. switching capacity\u003c\/th\u003e\u003ctd\u003e2 A (inductive)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRun-on time\u003c\/th\u003e\u003ctd\u003eadjustable from 1 to 25 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAmbient temperature\u003c\/th\u003e\u003ctd\u003e0 to 50 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eProtection class\u003c\/th\u003e\u003ctd\u003eII\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP 20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e130 x 82 x 43 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePotential-free switching contact\u003c\/li\u003e\u003cli\u003eAdjustable run-on time\u003c\/li\u003e\u003cli\u003eSurface mounting\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53736217149781,"sku":"5401220800","price":246.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-SQA_faceaea1-12b1-4072-814e-d8c14df9bbe7.jpg?v=1776780597"},{"product_id":"sp-tg-k","title":"S\u0026P TG Temperature Sensors for Duct, Room and Pipe Contact","description":"\u003cp\u003e\u003cstrong\u003eS\u0026P TG Temperature Sensors for Duct, Room and Pipe Contact\u003c\/strong\u003e: temperature sensors from S\u0026P for ventilation controls: duct sensors, contact sensors (also for frost protection) and room temperature sensors. Options under type: TG-K, duct temperature sensor, TG-K NTC 4M, duct temperature sensor, TG-K3\/PT1000, duct temperature sensor PT1000, TG-A, contact sensor, TG-A1\/PT1000, contact sensor frost protection and TG-R5, room temperature sensor.\u003c\/p\u003e\n\u003ch3\u003eThe versions in detail\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTG-K3\/PT1000, duct temperature sensor PT1000:\u003c\/strong\u003e S\u0026amp;P TG-K3\/PT1000 is a duct temperature sensor with Pt 1000 sensor from S\u0026amp;P. In the data sheets of the CADB\/T-HE PRO-REG ventilation units, S\u0026amp;P lists it as an external supply air sensor that is required as an accessory for the external BA-AF HE, BA-AFC HE and BA-DX HE coils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTG-A, contact sensor:\u003c\/strong\u003e S\u0026amp;P TG-A is a frost protection sensor (contact sensor) from S\u0026amp;P for the AQUA24 hot water heating coils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTG-A1\/PT1000, contact sensor frost protection:\u003c\/strong\u003e S\u0026amp;P TG-A1\/PT1000 is a contact sensor with Pt 1000 sensor from S\u0026amp;P for the frost protection of hot water heating coils on ventilation units with PRO-REG control. In the CADB\/T-HE PRO-REG data sheets, S\u0026amp;P lists it as a required accessory for the external BA-AF HE and BA-AFC HE coils, and in the RHE data sheet as a frost protection sensor for an external water coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTG-R5, room temperature sensor:\u003c\/strong\u003e S\u0026amp;P TG-R5 is a room temperature sensor (Pt 1000) from S\u0026amp;P. According to S\u0026amp;P, the TG-R5 is only to be used for the CAIB\/CAIT PRO-REG series supply air units.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cp\u003eData per version:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTG-K\u003c\/th\u003e\n\u003cth\u003eTG-K3\/PT1000, duct temperature sensor PT1000\u003c\/th\u003e\n\u003cth\u003eTG-A, contact sensor\u003c\/th\u003e\n\u003cth\u003eTG-A1\/PT1000, contact sensor frost protection\u003c\/th\u003e\n\u003cth\u003eTG-R5, room temperature sensor\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor element\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003ePt 1000\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003ePt 1000\u003c\/td\u003e\n\u003ctd\u003ePt 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003eexternal supply air sensor\u003c\/td\u003e\n\u003ctd\u003efrost protection sensor (contact sensor)\u003c\/td\u003e\n\u003ctd\u003econtact sensor for frost protection\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003ctd\u003eCADB\/T-HE PRO-REG with BA-AF HE, BA-AFC HE or BA-DX HE\u003c\/td\u003e\n\u003ctd\u003eAQUA24 hot water heating coils\u003c\/td\u003e\n\u003ctd\u003ehot water heating coils on PRO-REG units, for example BA-AF HE and BA-AFC HE (CADB\/T-HE PRO-REG) and external water coils on RHE\u003c\/td\u003e\n\u003ctd\u003eCAIB\/CAIT PRO-REG supply air units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNote on variants\u003c\/h3\u003e\n\u003cp\u003eSelect the required version under Type.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eItem number\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-K, duct temperature sensor\u003c\/td\u003e\n\u003ctd\u003e8000103728\u003c\/td\u003e\n\u003ctd\u003eTG-K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-K NTC 4M, duct temperature sensor\u003c\/td\u003e\n\u003ctd\u003e5416049800\u003c\/td\u003e\n\u003ctd\u003eTG-K NTC 4M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-K3\/PT1000, duct temperature sensor PT1000\u003c\/td\u003e\n\u003ctd\u003e8000132257\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-A, contact sensor\u003c\/td\u003e\n\u003ctd\u003e8000102032\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-A1\/PT1000, contact sensor frost protection\u003c\/td\u003e\n\u003ctd\u003e8000132295\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTG-R5, room temperature sensor\u003c\/td\u003e\n\u003ctd\u003e8007030402\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTG-K3\/PT1000, duct temperature sensor PT1000: According to S\u0026amp;P, required accessory for the external BA-AF HE, BA-AFC HE and BA-DX HE coils on CADB\/T-HE PRO-REG\u003c\/li\u003e\n\u003cli\u003eTG-K3\/PT1000, duct temperature sensor PT1000: S\u0026amp;P does not state measuring range, degree of protection or dimensions in these documents.\u003c\/li\u003e\n\u003cli\u003eTG-A, contact sensor: Contact sensor for frost protection on hot water heating coils\u003c\/li\u003e\n\u003cli\u003eTG-A, contact sensor: S\u0026amp;P does not state further technical data on the product page.\u003c\/li\u003e\n\u003cli\u003eTG-A1\/PT1000, contact sensor frost protection: Contact sensor for monitoring the coil return temperature (frost protection)\u003c\/li\u003e\n\u003cli\u003eTG-A1\/PT1000, contact sensor frost protection: S\u0026amp;P does not state measuring range, degree of protection or dimensions in these documents.\u003c\/li\u003e\n\u003cli\u003eTG-R5, room temperature sensor: Only for the CAIB\/CAIT PRO-REG supply air units\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"TG-K, duct temperature sensor","offer_id":53736274428245,"sku":"8000103728","price":94.99,"currency_code":"EUR","in_stock":true},{"title":"TG-K NTC 4M, duct temperature sensor","offer_id":55302795362645,"sku":"5416049800","price":113.49,"currency_code":"EUR","in_stock":true},{"title":"TG-K3\/PT1000, duct temperature sensor PT1000","offer_id":55387319632213,"sku":"8000132257","price":100.49,"currency_code":"EUR","in_stock":true},{"title":"TG-A, contact sensor","offer_id":55387319664981,"sku":"8000102032","price":90.49,"currency_code":"EUR","in_stock":true},{"title":"TG-A1\/PT1000, contact sensor frost protection","offer_id":55387319697749,"sku":"8000132295","price":78.49,"currency_code":"EUR","in_stock":true},{"title":"TG-R5, room temperature sensor","offer_id":55387319730517,"sku":"8007030402","price":161.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/11259928183125.jpg?v=1791483987"},{"product_id":"sp-vchv-set","title":"S\u0026P VCHV-Set Transmitter 0-10 V, Transformer 230\/24 V","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P VCHV-Set\u003c\/strong\u003e is a 0 to 10 V differential pressure transmitter with setpoint specification, supplied as a set together with the TRAFO 24 DC transformer (230 V to 24 V DC). According to S\u0026amp;P, it is used for differential pressure measurement for constant pressure operation (COP) and constant airflow operation (CAV); the transmitter outputs a 0 to 10 V signal.\u003c\/p\u003e\n\u003cp\u003eAccording to S\u0026amp;P, the K factor of the fan must be known for CAV operation. The transmitter is suitable for gaseous, non-aggressive media and has a housing made of impact-resistant plastic.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eScope of delivery\u003c\/th\u003e\u003ctd\u003eVCHV transmitter with display, TRAFO 24 DC, measuring nozzle set\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0 to 2,500 Pa\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOutput signal\u003c\/th\u003e\u003ctd\u003e0 to 10 V \/ 4 to 20 mA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSupply voltage\u003c\/th\u003e\u003ctd\u003e24 V DC, 1~ 230 V with the transformer from the set\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eConsumption\u003c\/th\u003e\u003ctd\u003e5 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eProtection rating\u003c\/th\u003e\u003ctd\u003etransmitter IP 54, transformer IP 67\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003etransmitter 79 x 75 x 38 mm, transformer 130 x 25 x 21 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003ctd\u003eL012800100\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eThe set point is adjusted on the VCHV transmitter; according to S\u0026amp;P, the control keeps the set value constant via the 0 to 10 V signal to the fan.\u003c\/li\u003e\u003cli\u003eListed in the S\u0026amp;P main catalogue 2026 as an accessory for, among others, TD-EVO PF ECOWATT, TD SILENT ECOWATT, JETLINE ECOWATT, VENT ECOWATT and UVF ECOWATT.\u003c\/li\u003e\u003cli\u003eAccording to S\u0026amp;P, the VCHV-Set enables constant airflow control for UVF ECOWATT, which compensates, for example, for increasing filter loading; operation via the ZSU-N time switch in the 230 V supply line is optionally possible.\u003c\/li\u003e\u003c\/ul\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"Default Title","offer_id":53736303821141,"sku":"L012800100","price":385.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-VCHV_c6db03b9-2053-4afb-bb9b-866ad0be82b1.jpg?v=1776780653"},{"product_id":"sp-sundp-sprd-010b-differenzdruckmessumformer","title":"S\u0026P SPRD-010B Differential Pressure Transmitter","description":"\u003cp\u003e\u003cstrong\u003eS\u0026amp;P SPRD-010B\u003c\/strong\u003e is a differential pressure transmitter from S\u0026amp;P for the RHE and CAIB\/CAIT PRO-REG ventilation units. According to S\u0026amp;P, it enables constant pressure operation (COP).\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eSupply voltage\u003c\/th\u003e\u003ctd\u003e12 to 24 V DC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePower consumption\u003c\/th\u003e\u003ctd\u003e5 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOutput signal\u003c\/th\u003e\u003ctd\u003e0.5 to 4.5 V DC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDegree of protection\u003c\/th\u003e\u003ctd\u003eIP 55\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e120 x 120 x 65 mm\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003cth\u003eArticle number\u003c\/th\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003eSPRD-010B 500\u003c\/td\u003e\u003ctd\u003e5416826200\u003c\/td\u003e\u003ctd\u003e0 to 500 Pa\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSPRD-010B 800\u003c\/td\u003e\u003ctd\u003e5416786900\u003c\/td\u003e\u003ctd\u003e0 to 800 Pa\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFor gaseous, non-aggressive media\u003c\/li\u003e\u003cli\u003eHousing made of impact-resistant plastic\u003c\/li\u003e\u003cli\u003eMeasuring nozzle set included\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eNote on variants\u003c\/h3\u003e\u003cp\u003eThe selection 500 or 800 indicates the measuring range in pascals. According to S\u0026amp;P, the 0 to 500 Pa measuring range is intended for RHE 700 and RHE 1300.\u003c\/p\u003e","brand":"S\u0026P Deutschland GmbH","offers":[{"title":"500","offer_id":53736457306453,"sku":"5416826200","price":296.49,"currency_code":"EUR","in_stock":true},{"title":"800","offer_id":53736457339221,"sku":"5416786900","price":296.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/SPDeutschland-SPRD_587dc25d-5d4e-4605-95da-1c126b329298.jpg?v=1776780948"},{"product_id":"rts01-ext-boden-kanalfuhler-ntc10kω-ip55-mit-3m-kabel-max-6m","title":"Frico RTS01 external floor and duct sensor, NTC 10 kΩ, IP55, 3 m cable","description":"\u003cp\u003e\u003cstrong\u003eFrico RTS01\u003c\/strong\u003e is an external temperature sensor for Frico thermostats. It measures the temperature as a floor or duct sensor at a different location from the thermostat itself. The sensor uses an NTC element with 10 kOhm and is supplied with a 3 m cable.\u003c\/p\u003e\u003cp\u003eFrico lists the RTS01 as an accessory for the RTI2 electronic two-stage thermostat. According to the RTI2 manual, the cable to the external sensor may be no longer than 6 m. Frico also lists the RTS01 as the external sensor for the TD10 range of thermostats. Please check before ordering whether your thermostat supports an NTC 10 kOhm sensor.\u003c\/p\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable class=\"wt-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eManufacturer\u003c\/th\u003e\u003ctd\u003eFrico\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eexternal floor and duct sensor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSensor\u003c\/th\u003e\u003ctd\u003eNTC, 10 kOhm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eProtection class\u003c\/th\u003e\u003ctd\u003eIP55\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eCable\u003c\/th\u003e\u003ctd\u003e3 m included\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMax. cable length\u003c\/th\u003e\u003ctd\u003e6 m\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eItem number\u003c\/th\u003e\u003ctd\u003eRTS01\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eAccessory for RTI2 and other Frico thermostats.\u003c\/li\u003e\u003cli\u003eFor measurements at floor level or in the air duct.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Frico GmbH","offers":[{"title":"Default Title","offer_id":54398243701077,"sku":"RTS01","price":18.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/PIM_RTS.jpg?v=1792887063"},{"product_id":"wanas-co2-sensor-co2control-und-co2rcontrol-fuer-lueftungsgeraete","title":"WANAS CO2 sensor CO2Control and CO2RControl for ventilation units","description":"\u003cp\u003eThe WANAS CO2 sensors measure the carbon dioxide concentration in the room and adjust the ventilation level of the WANAS ventilation unit to demand. This also allows zone ventilation based on CO2 levels. The CO2RControl communicates by radio (868 MHz) with the controller.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2-controlled demand ventilation for WANAS ventilation units\u003c\/li\u003e\n\u003cli\u003eCO2RControl with 868 MHz radio, supply 15 to 24 V according to the manufacturer\u003c\/li\u003e\n\u003cli\u003eColours white or black\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data according to the manufacturer\u003c\/h3\u003e\n\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003cth\u003ePower consumption\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eCO2Control (wired), White\u003c\/td\u003e\u003ctd\u003e1.5 W\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eCO2RControl (radio), White\u003c\/td\u003e\u003ctd\u003e1 W\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eVersions\u003c\/h3\u003e\n\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eItem number\u003c\/th\u003e\u003cth\u003eModel\u003c\/th\u003e\u003cth\u003eColour\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK CO2CONTR\u003c\/td\u003e\u003ctd\u003eCO2Control (wired)\u003c\/td\u003e\u003ctd\u003eWhite\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK CO2 CZAR\u003c\/td\u003e\u003ctd\u003eCO2Control (wired)\u003c\/td\u003e\u003ctd\u003eBlack\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK CO2RCONTR\u003c\/td\u003e\u003ctd\u003eCO2RControl (radio)\u003c\/td\u003e\u003ctd\u003eWhite\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK CO2R CZAR\u003c\/td\u003e\u003ctd\u003eCO2RControl (radio)\u003c\/td\u003e\u003ctd\u003eBlack\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesign, balancing, installation and maintenance by a qualified ventilation contractor. On request we can arrange an installation partner for mounting, commissioning and maintenance.\u003c\/li\u003e\n\u003cli\u003eTechnical data according to the manufacturer WANAS. The manufacturer data sheet and instructions apply; they are available in English or Polish.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.wanas.pl\/wp-content\/uploads\/2025\/04\/Instrukcja-instalacji-i-obslugi-Co2-Control.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operating manual CO₂CONTROL sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.wanas.pl\/wp-content\/uploads\/2025\/04\/Instrukcja-instalacji-i-obslugi-Co2RControl.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operating manual CO₂RCONTROL sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.wanas.pl\/wp-content\/uploads\/2025\/04\/172163744857-Wentylacja-Strefowa.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZone ventilation information CO₂RCONTROL sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManufacturer: WANAS Sp. z o.o., Nisko, Poland, www.wanas.pl\u003c\/p\u003e","brand":"Wanas","offers":[{"title":"CO2Control (wired) \/ White","offer_id":55549365682517,"sku":"RE-CZUJNIK CO2CONTR","price":338.49,"currency_code":"EUR","in_stock":true},{"title":"CO2Control (wired) \/ Black","offer_id":55549365715285,"sku":"RE-CZUJNIK CO2 CZAR","price":340.99,"currency_code":"EUR","in_stock":true},{"title":"CO2RControl (radio) \/ White","offer_id":55549365748053,"sku":"RE-CZUJNIK CO2RCONTR","price":362.49,"currency_code":"EUR","in_stock":true},{"title":"CO2RControl (radio) \/ Black","offer_id":55549365780821,"sku":"RE-CZUJNIK CO2R CZAR","price":364.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/169347339331-600x600-CO2_control-1.png?v=1793113620"},{"product_id":"wanas-temperaturfuehler-und-steuerleitung-fuer-lueftungsgeraete","title":"WANAS temperature sensors and control cable for ventilation units","description":"\u003cdiv class=\"wt-nmg-hinweis\" data-wt-nmg=\"1\"\u003e\u003cp\u003e\u003cstrong\u003eOnly available in combination with a Wanas ventilation unit, shipped together with the unit.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe control cable is priced per metre, please enter the required length in metres as the order quantity.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eAccessories for the control of WANAS ventilation systems: the EXTRA TEMP PT-1000 duct sensor measures the temperature downstream of a heating or cooling coil in the duct. The W-1000 sensor is required for an air or brine ground heat exchanger. The shielded 4 x 0.14 mm² control cable connects the ventilation unit to the controller.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePT-1000 duct sensor for coil monitoring\u003c\/li\u003e\n\u003cli\u003eW-1000 sensor for ground heat exchangers\u003c\/li\u003e\n\u003cli\u003eControl cable 4 x 0.14 mm², shielded, PVC core insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVersions\u003c\/h3\u003e\n\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eItem number\u003c\/th\u003e\u003cth\u003eItem\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK EXTRA TEM\u003c\/td\u003e\u003ctd\u003eDuct sensor EXTRA TEMP PT-1000\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRE-CZUJNIK W-1000\u003c\/td\u003e\u003ctd\u003eTemperature sensor W-1000 for ground heat exchanger\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eRE-PRZEWÓD 4X0,14\u003c\/td\u003e\u003ctd\u003eControl cable 4 x 0.14 mm², shielded, price per metre\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesign, balancing, installation and maintenance by a qualified ventilation contractor. On request we can arrange an installation partner for mounting, commissioning and maintenance.\u003c\/li\u003e\n\u003cli\u003eTechnical data according to the manufacturer WANAS. The manufacturer data sheet and instructions apply; they are available in English or Polish.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManufacturer: WANAS Sp. z o.o., Nisko, Poland, www.wanas.pl\u003c\/p\u003e","brand":"Wanas","offers":[{"title":"Duct sensor EXTRA TEMP PT-1000","offer_id":55549366042965,"sku":"RE-CZUJNIK EXTRA TEM","price":21.49,"currency_code":"EUR","in_stock":true},{"title":"Temperature sensor W-1000 for ground heat exchanger","offer_id":55549366075733,"sku":"RE-CZUJNIK W-1000","price":22.99,"currency_code":"EUR","in_stock":true},{"title":"Control cable 4 x 0.14 mm², shielded, price per metre","offer_id":55549366108501,"sku":"RE-PRZEWÓD 4X0,14","price":1.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/1247\/2405\/files\/Dlaczego-warto-wybrac-wymiennik-entalpiczny-dla-WANAS-Zapewnia-wlasciwa-wentylacje-z-odzyskiem-ciepla-i-wilgoci-w-instalacjach-z-centralami-WANAS.-Optymalizuje-komfort-i-jakosc-powiet.png?v=1793113635"}],"url":"https:\/\/wohnungstechnik.de\/en\/collections\/kanalfuehler-sensoren.oembed","provider":"Wohnungstechnik.de","version":"1.0","type":"link"}